4.3.3

BEA 070 configuration

After installing the BEA software, the device interface
of the BEA 070 has to be set. The BEA 070 can be con-
nected by way of either the USB connecting cable or
Bluetooth to a PC/Laptop.
1. Select "Start >> All Programs >> Bosch >> Diagnos-
tics >> Central Device Communication" or left-click
on " " in the task bar.
 CDC – Central Device Communication is opened.
2. Select "Settings >> Device interfaces".
i
Pressing <F1> opens the Online Help for a display
of the most important information on interface
settings.
3. Configure the BEA 070 in the RTM Group (USB or
Bluetooth).
 BEA 070 is ready for operation.
4. Start the BEA-AU-OBD software.
4.4

Program description

i
Refer to the Online Help for further details on the
BEA-AU-OBD system software.
Robert Bosch GmbH
4.5

Preparation

4.5.1

Vehicle

!
Please observe safety instructions.
R
The engine must be at operating temperature
(according to manufacturer's specification).
R
The exhaust pipe must not be leaking.
R
The engine settings, such as idle speed, start of de-
livery, fuel quantity and full load stop, must conform
to the manufacturer's specification.
4.5.2

BEA 070

i
The BEA 070 requires a warm-up time of approx.
3 minutes after switch-on. No exhaust gas measure-
ment is possible during this time.
i
To ensure that exhaust gas measurement conforms
to standards, the BEA 070 must not be positioned
directly in the flow of exhaust gas (immediately in
front of the exhaust pipe). The exhaust gas sampling
hose must not be kinked!
1. The exhaust gas sampling probe and sampling hose
must be checked for clogging and damage before
measurement.
2. If the vehicle has an exhaust gas recirculation hose
(special accessory), attach this to the connection
(Fig. 1, Pos. 10) of the BEA 070 and connect to the
extraction system.
i
The suction power of the extraction system must not
exceed 20 m/s, in order to prevent false measure-
ment results. Only extract the exhaust gas using an
extraction system with funnel.
3. Replace the oil dipstick in the engine compartment
with an oil temperature sensor. To do so, adjust the
sealing cone of the oil temperature sensor to the
insertion length of the dipstick.
4. Attach and connect the rotational speed sensor.
5. Only insert the exhaust gas sampling probe in
the exhaust pipe after the warm-up phase of the
BEA 070 and following several cleaning bursts of
throttle by a warm engine.
| BEA 070 | 23