General Technical Data
Shock during operation
The following table specifies permissible shock during operation. The test was per-
formed in accordance with IEC 60068-2-27.
Shock Duration
11 msec
Climatic ambient conditions
The following climatic ambient conditions apply.
Table 6-1
Ambient Condition
Temperature
Temperature change 3 K/min
Air pressure
Relative humidity
Concentration of -
pollutants
6.4
Information on isolation tests, protection class,
protection rating and nominal voltage of the ET 200R
Protection rating, IP65
IP65 protection rating in accordance with IEC 529 for the ET 200R distributed I/O
device
• Protection against dust and total protection against accidental touch
• Protection against jet of water from a nozzle directed from all sides at the
housing. The water may not cause damage.
Note
The above protection ratings only apply when the ET 200R is completely closed.
Close all unused plugs with the appropriate protective caps.
6–4
Shock Form
Half sine
Ambient conditions
Application Area
From 0 ° to 55 °C
Up to 95%
SO
: < 0,5 ppm;
2
rel. humidity < 60%, no condensation
H
S: < 0,1 ppm;
2
rel. humidity < 60%, no condensation
Acceleration
15 g
3 shocks each in +/- direction in
each of the 3 vertical axes
(4)J31069-D0427-U001-A2-7618
Amount
Remarks
Not tested
No condensation
Test:
10 ppm; 4 days
1 ppm; 4 days