(the setpoint temperature display is blank in
the AUTO mode). The system will now auto-
matically switch between heating and cooling,
depending on the actual room temperature.
Auto Changeover Switch Positions
ON
1
2
Switch #1 ON
Switch #2 OFF
Switch #3 (see Energy Management Recovery)
In the AUTO mode, the thermostat will not allow
the temperature separation between the highest
heat setting and the lowest cool setting to be less
than 1 F. For example, if the highest heat setting
is 75 F, the lowest cool setting cannot be below
77 F (see diagram at right).
14
Group B
Option
Switches
3
NOTE
79
COOLING TEMPERATURES
78
77
76
DEAD BAND 1°F
75
74
HEATING TEMPERATURES
73
• TWO HOUR TEMPERATURE OVERRIDE —
Press
or
the temperature you want. The thermostat will
override current programming and keep the
room temperature at the selected temperature
for two hours. After two hours, the thermostat
will automatically revert to the program.
• HOLD TEMPERATURE — The thermostat
can hold any temperature within its range for
an indefinite period, without reverting to the
program. Press
played. Then choose the desired hold tem-
perature by pressing
thermostat will hold the room temperature at
until the display shows
HOLD
. HOLD will be dis-
COPY
or
. The