Always remove the battery from the machine before starting any work on the machine.
Problem
Running time is too short
Battery gets stuck during insertion in the
machine/charger
Battery does not charge although the LEDs
on the charger are green
LED on charger flashes red
1)
STIHL recommends STIHL servicing dealers
MSA 160 T
Cause
Battery is not completely charged
Service life of battery has been reached
or exceeded
Cutting attachment dirty
Guides / contacts dirty
Battery too hot / too cold
(1 LED on battery is red)
No electrical contact between charger
and battery
Malfunction of battery
(4 LEDs on battery flash red for
approx. 5 seconds)
Malfunction in charger
Remedy
Charge battery
1)
Check battery
and replace
Clean cutting attachment
Carefully clean guides / contacts
Let the battery cool down / let the battery
warm up gradually at temperatures of
approx. 15 °C - 20 °C (59 °F - 68 °F)
Operate the charger only in a closed, dry
space at ambient temperatures of 5 °C -
40 °C (41 °F - 104 °F)
Remove battery and reinsert it
Remove the battery from the machine
and reinsert it. Turn on the machine – if
the LEDs still flash, the battery is faulty
and must be replaced
Have charger checked by a servicing
1)
dealer