2.1.9 Removing the Toner Bottle Sensor

1) Remove the front cover. (See 2.1.1.4.)
2) Remove the screw [1], and detach the
toner supply cover open/closed detect-
ing switch [2] from the body.
3) Disconnect the connector [3].
4) Remove the 2 screws [4], and detach the
unit [5].
5) Disconnect the connector [6], and de-
tach the toner bottle sensor [7].

2.1.10 Removing the Waste Toner Full Sensor

1) Open the cartridge cover.
2) Remove the screw [1].
3) Disconnect the connector [2], and de-
tach the waste toner full sensor [3].
For removal, place a sheet
of paper to avoid contact
with the transfer charging
roller.