Opening The Gas Isolation Valve; Opening Service Valves; Switch On The Boiler; Check Water Pressure - Worcester GB162 Series User Instructions

Wall hung gas fired condensing boiler
Hide thumbs Also See for GB162 Series:
Table of Contents

Advertisement

Operating the appliance

3.2

Opening the gas isolation valve

▶ Push the gas isolation valve in and turn anti-clockwise until the valve
lines up with the gas line.
Fig. 2
Opening the gas isolation valve
3.3

Opening service valves

▶ Open both service valves so that the tap lines up with pipework.
Fig. 3
Opening service valves
3.4

Switch on the boiler

▶ Put the on/off switch to position "1" ( figure 5, [1]).
3.5

Check water pressure

For the boiler to work efficiently, the normal water pressure must be
between 1.0 and 2.0 bar.
▶ Ask the installer whether a higher pressure is necessary.
▶ Read off the water pressure on the display ( Chapter 4.1, page 7).
▶ Top up the heating system if necessary ( Chapter 6.1, page 8).
Fig. 4
Read off the water pressure
3.6

Setting the maximum boiler temperature

▶ Set the maximum boiler temperature required in the setup menu
( Chapter 4.2).
6
The heating and DHW operations can be switched on and off
independently of one another.
3.7

Heating controller settings

Some of the functions described in this document change when
connecting a heating controller, i.e. room thermostat or weather-
compensated controls. The controls exchange parameters with the
boiler.
▶ You should therefore carefully read the operating instructions for the
corresponding heating controls.
4
Operating the appliance
0010025259-001
1
2
Fig. 5
Control panel
[1]
On/off switch
[2]
Reset key
[3]
Chimney sweep key
[4]
Help key
[5]
Display
[6]
Menu key
[7]
Down key
0010025260-001
[8]
Up key
[9]
Diagnostic plug
[10] Burner LED
The front of the boiler contains a control panel with the following
elements:
On/off switch
The boiler can be switched on or off via the on/off switch. The power
supply is not interrupted.
Reset c key
The boiler can be restarted via the c key in the event of blocking faults
( Chapter 7).
Chimney sweep d key
The boiler can be brought into operation via the d key in order to carry
out measurements. Used for servicing.
Info L key
The boiler status can be read out via the L key
Display
Display values, settings and codes can be read off the display. If the
boiler is switched on via the mains isolator, all symbols appear briefly in
the display.
0010020120-001
Status display
Display when the boiler is switched on (approx. 1 second)
3
4
5
10
6 7
Commercial Boiler Series – 6720814333 (2019/05)
8
9
0010025261-001