Advanced Functions For Heating Circuits; Advanced Functions For Dhw - Bosch Control 8311 Operating Instructions Manual

Table of Contents

Advertisement

4.2

Advanced functions for heating circuits

You need the extended functions to change the factory defaults of your
heating circuit.
If the system has several heating circuits, the settings for each heating
circuit must be made separately.
Extended function
Explanation/Function
Party function
Setting which specifies how long the heating system heats at the preset
room temperature in heating mode.
Pause function
Setting that specifies how long the heating system heats up to the preset
room temperature in setback mode.
Holiday function
Setting that specifies how long the heating system heats up to the preset
room temperature in setback mode.
Table 4 Advanced functions for heating circuits
4.3

Advanced functions for DHW

setting
Adjustment range
Circulation time program
On
Auto
Off
Switch-on frequency per
On/Off
hour
Once on
Twice on
Three times on
Four times on
Five times on
Six times on
Once-only cylinder charging On
Thermal disinfection
On
Holiday
Off/On
Table 5 Advanced functions for DHW
Control 8311/8313 – 6720859790 (2020/02)
Explanation
Setting the operating mode of the DHW
circulation pump
The DHW circulation pump runs
continuously.
The DHW circulation pump operates
independently of the heating circuits
according to the custom time program at the
intervals set ( Chapter 5.6.1, page 21).
The DHW circulation pump is not activated.
The DHW circulation pump is switched on
for the duration of the once-only cylinder
charging operation via the Once-only
cylinder charging function.
Setting that specifies how often the DHW
circulation pump runs every hour for 3
minutes.
On = continuous operation
Off = switched off
Option of heating the DHW once, although
the system is in setback mode.
Option of starting the Thermal disinfection
immediately.
Setting that specifies how long the DHW
settings are not taken into account.
Remark
The function is immediately active
following the input ( Chapter 5.3.2,
page 20).
The function is immediately active
following the input ( Chapter 5.3.3,
page 20).
The holiday period can be set via a year
calendar ( Chapter 5.3.1, page 19).
Remark
The function depends on the factory
defaults which vary according to the
system.
( Chapter 5.6.1, page 21)
You can reduce the operating costs of the
DHW circulation pump by using intermittent
operation.
The function depends on the factory
defaults which vary according to the
system.
( Chapter 5.6.1, page 21)
( Chapter 5.6.2, page 21)
The holiday period can be set via a year
calendar ( Chapter 5.3.1, page 19).
Settings
17