Controller Operating Status Indicators - Banner A-GAGE MINI-ARRAY MAC Series Instruction Manual

Measuring light screen system
Table of Contents

Advertisement

System Operation

6.2 Controller Operating Status Indicators

Output 1
(labeled OUT1, V out,
I out, OUT or OUT 1
depending on model)
Alarm
Gate
Align
Diag 1,2,3
Diag 1
Diag 2
Diag 3
OUT 1
DIAG 1
ALARM
DIAG 2
GATE
DIAG 3
ALIGN
15 14 13 12 11 10
Figure 6-2. Controller front panel
36
P/N 43298 rev. E
Models MAC-1,
MACP-1, MACN-1,
MACV-1, MACI-1:
Red
Models MAC16N-1
MAC16P-1:
Models MAC-1,
MACP-1, MACN-1,
MACV-1, MACI-1:
Red
Models MAC16N-1
MAC16P-1:
Red
All Models
All Models
Green
All Models
Normal
Receiver
Condition
Green
ON
Red
OFF
Red
OFF
MINI-ARRAY
CONTROLLER
15
14 13 12 11 10
9
8
7
6
5
T/R T/R DRN COM +12V
30V
-
+
-
+
500mA
WH BK
BU
RS485
10-30V DC
150mA
Max
GATE
Max.
OUT 1
5 Wires
ALARM
EMTR
RCVR
9
8
7
6
5
displays the status of Output #1
displays the status that at least one output is active
displays the status of Output #2. Output #2 may be assigned
to an Analysis Mode or may be used as a system diagnostics
Alarm, or as a Trigger alarm for gating another MINI-ARRAY
System
displays the status of Output #16
displays the status of the Gate input
indicates proper sensor alignment and a clear light screen. This
indicator is ON when the green or green and yellow LEDs of the
receiver are ON
used in combination to indicate system status as shown below:
Emitter/
Emitter
Receiver
Error
Error
Mismatch
ON
ON
ON
ON
OFF
ON
OFF
ON
ON
MAC-1
RS-232
4
3
2
1
F1
BR
L2 L1
16-30V DC
1.2A Max.
RS-232
2 - TX
3 - RX
5 - COM
POWER
4
3
2
1
Instruction Manual
Controller
EEPROM
Error
Error
OFF
OFF
ON
OFF
OFF
ON
Banner Engineering Corp.
Minneapolis, MN U.S.A.
www.bannerengineering.com • Tel: 763.544.3164
®
MINI-ARRAY
ROM/RAM
Error
OFF
ON
ON

Hide quick links: