3.4.7 Model MAC16N-1 Controller Hookup
Terminals #15 through #30 are open-collector NPN transistor outputs rated at
30V dc max., 150 mA max. They are protected against overload and short circuits.
All outputs are current sinking.
Controller terminal #15 (output #16) may be used as an output or as an alarm.
Whenever this output is active, the red Alarm LED is ON.
16 Solid-state Ouputs
15
30
through
150 mA Max each
Figure 3-11. Model MAC16N-1 hookup

3.5 System Power

Connect a 16 to 30V dc source to controller terminals #1 (V+) and #2 (V–). Connect
a good earth ground to terminal #3. A good earth ground is important for providing
electrical and RF noise immunity to the MINI-ARRAY System. The dc power source
must supply 1.25 amps (worst case) when using the longest (6') sensors. See
Specifications (Section 2) for more information.

3.6 Gate

Connect a switched 10 to 30V dc source as a gating input (if required) between
controller terminal #11 (+) and #12 (-). Voltage is typically switched by the open-
collector output transistor of a dc sensing device.

3.7 Serial Communication

RS-485 (Models MAC-1, MACP-1, and MACN-1 only)
Connect RS-485 lines (if used) to terminals #13 (+) and #14 (-).
RS-232
Prepare an RS-232 cable using a DB-9 male connector with the connections shown in
Figure 3-12.
NOTE:
DO NOT use a "null modem" RS-232 cable.
18
P/N 43298 rev. E
9
14
13
12
11
10
8
NC
NC
NC
NC
+
10-30V dc
Gate
RECEIVER CABLES
Power
7
6
5
4
3
2
1
F1
V-
V+
16-30V dc
1.2 A Max.
EMITTER and
Banner Engineering Corp.
MINI-ARRAY
Instruction Manual
RS-232
5
3
2
DB-9 Pin #
Function
2
Transmit (TX)
3
Receive (RX)
Ground (GND)
5
Figure 3-12. DB9 serial connector