INSTRUCTIONS for
These INSTRUCTIONS are for experienced operators. If you are not fully familiar with the principles of operation and safe prac-
tices for oxy-fuel gas equipment, we urge you to read our booklet "Precautions and Safe Practices for Welding, Cutting and
Heating", Form 2035. Do NOT permit untrained persons to install, operate, or maintain this equipment. Do NOT attempt to install
or operate this equipment until you have read and fully understand these instructions. If you do not fully understand these
instructions, contact your supplier for further information.
The cutting torches covered by these instructions are listed by third parties only when using parts manufactured
by ESAB Welding & Cutting Products, to the specifications on file with third party listed, and when they are used
in the gas service for which they are designed and listed. The use of other parts that cause damage or failure to the equipment will
void the manufacturer's warranty.
I.
DESCRIPTION
The C-60 and C-60-S Machine Cutting Torches are
for use with any of the commonly used fuel gases such
as acetylene, natural gas, propane and many of the
proprietary gases. A minimum of 10 psi fuel gas pres-
sure is required for proper operation.
The basic difference between the C-60 and C-60-S
torches is in their overall length. The C-60 torch is ap-
proximately 6 feet long, while the C-60-S is approxi-
mately 2 1/2 feet long. The 1700-ACA-2 Power Cut-
ting Attachment is only for use with the C-60 torch.
II. INSTALLATION AND CONNECTION
A. INSTALLATION
1. A filter designed to screen out dirt and scale should
be installed upstream of the cutting oxygen regu-
lator which supplies the C-60 Torch. Use of a filter
reduces the possibility of accidental hose burn-
outs.
The 1-in. NPT Pipeline Filter Assembly (P/N
2116734) is recommended if the cutting oxygen
Be sure this information reaches the operator.
You can get extra copies through your supplier.
C-60 and C-60-S
MACHINE CUTTING TORCHES and
1700-ACA-1
POWDER CUTTING ATTACHMENT
supply regulator is an Oxweld R-52 feeding a single
cutting station. In the case of multiple torch instal-
lations supplied by a single oxygen regulator, such
as an Oxweld R-83, filter (P/N 2116735) is recom-
mended.
2. A 1-in. quick opening full flow shutoff valve should
be installed in the cutting oxygen hose line at least
6 feet ahead of the torch and convenient to the op-
erating position.
3. For control of the preheat gases, "C" size oxygen
and acetylene needle valves should be inserted in
the preheat oxygen and fuel gas hose lines at least
6 feet ahead of the torch.
Standard commercial valves can be used after they
are cleaned and lubricated, to oxygen standards,
as described in maintenance procedures.
4. If using the 1700-ACA-2 Power Cutting Attachment
(10Y95) on the C-60, the ACV-4 Powder Pinch
Valve (16X36) should be installed in the powder
hose line about 5 feet ahead of the torch and con-
venient to the operator.
5. Connect the front clamp of powder cutting attach-
ment to front body of torch. Connect the two rear
clamps to the cutting-oxygen tube on the torch. (See
Fig. 2.)
1
F-9040-P
May, 2009

Advertisement

Table of Contents
loading

Summary of Contents for ESAB OXWELD C-60

  • Page 1 The cutting torches covered by these instructions are listed by third parties only when using parts manufactured by ESAB Welding & Cutting Products, to the specifications on file with third party listed, and when they are used in the gas service for which they are designed and listed. The use of other parts that cause damage or failure to the equipment will void the manufacturer’s warranty.
  • Page 2: User Responsibility

    reaD anD unDerstanD instruction manual Before installing or operating. protect Yourself anD others! caution these instructions are for experienced operators. if you are not fully familiar with the prin- ciples of operation and safe practices for gas welding and cutting equipment, we urge you to read our booklet, “precautions and safe practices for gas Welding, cutting, and heating,”...
  • Page 3: Safety Precautions

    SAFETY PRECAUTIONS This symbol appearing in this manual means Attention! Be Alert! Your safety is involved. Used to call attention to immediate hazards which, if not avoided, will result in immediate, serious personal injury or loss of life. Used to call attention to potential hazards which could result in personal injury or loss of life.
  • Page 5: Operation

    B. CONNECTION quently; (3) operating pressures are correct; and (4) throttle valves are adjusted properly. Should a flash- 1. Hoses — Use 3/4 in. cutting oxygen hose with “D” back occur, IMMEDIATELY shut off the torch. Allow it size fittings, 1/2-in. preheat oxygen and fuel gas to cool off for at least a minute.
  • Page 6: Maintenance

    To clean the mixer disk center orifice, use a No. 5 drill. mentioned in these instructions, return the equipment To clean the outer orifices use a No. 51 drill. Other to ESAB Remanufacturing Center, 411 S. Ebenezer cleaning tools tend to enlarge or bell-mouth the ori- Road, Florence, SC 29501.
  • Page 7: Optional Accessories

    When replacement of the cutting oxygen pressure If orifices of the cutting nozzles become clogged, clean gauge is necessary, apply a single turn of Teflon tape them by hand with the correct size drills or soft brass on the new gauge fitting threads and screw the gauge or copper wire.
  • Page 12 ESAB Welding & Cutting Products, Florence, SC Welding Equipment COMMUNICATION GUIDE - CUSTOMER SERVICES A. CUSTOMER SERVICE QUESTIONS: Order Entry Product Availability Pricing Delivery Order Changes Saleable Goods Returns Shipping Information Eastern Distribution Center Telephone: (800)362-7080 / Fax: (800) 634-7548...

This manual is also suitable for:

Oxweld c-60-sOxweld 1700-aca-1

Table of Contents