Night Silent Operation Setting
Night Silent Operation Setting
1. Open the panel of outdoor unit.
2. Set the DIP SW01N as below Fig.
DIP SW01N
DIP Switch2
ON
1
2
3
4
3. Close the panel
WARNING: Do not open the panel when operating
the product.
Self-diagnosis Function
Error Indicator (Outdoor)
Outdoor Unit Error
Ex) Error 21
(DC Peak)
Error Code
21
DC Peak(IPM Fault)
22
Max. CT(CT2)
23
DC Link Low Volt.
24
Pressure switch/Heater Sink.
26
DC Comp Position Error
27
PSC Fault Error
28
DC Link High Volt.
29
Comp Over Current
32
D-Pipe High(Inv.)
41
Inv. D-Pipe Th Error(Open/Short)
44
Outdoor air Th Error(Open/Short)
45
Cond. Middle Pipe Th Error(Open/Short)
46
Suction Pipe Th Error(Open/Short)
48
Cond. Out-Pipe Th Error(Open/Short)
51
Capacity over
53
Communication Error(Indoor÷Outdoor)
60
EEPROM Error(Outdoor)
61
Cond. Middle Pipe High
62
Heatsink Error(High)
65
Heatsink Th Error(Open/Short)
67
BLDC motor fan lock(Outdoor)
73
PFC Fault Error(S/W)
h Repeatedly after LED1 is turned on and off as the Error code number of tens digit, LED2 is turned on and
off as the Error code number of single-digit.
16
ON
Night Silent Operation -ON
OFF
Night Silent Operation - OFF
2 Times
LED01G
(RED)
1 Sec.
1 Time
LED02G
(GREEN)
2 Sec.
Description
Function
2 Times
2 Times
1 Sec.
1 Sec.
1 Time
1 Time
2 Sec.
LED 1 (Red)
LED 2 (Green)
2times ◑
1time ◑
2times ◑
2times ◑
2times ◑
3times ◑
2times ◑
4times ◑
2times ◑
6times ◑
2times ◑
7times ◑
2times ◑
8times ◑
2times ◑
9times ◑
3times ◑
2times ◑
4times ◑
1time ◑
4times ◑
4times ◑
4times ◑
5times ◑
4times ◑
6times ◑
4times ◑
8times ◑
5times ◑
1time ◑
5times ◑
3times ◑
6times ◑
0
6times ◑
1time ◑
6times ◑
2times ◑
6times ◑
5times ◑
6times ◑
7times ◑
7times ◑
3times ◑
Indoor status
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF