Fig. 15 - - Example of Hose Clamp Installation
6. If trap comes unassembled, the components will require
assembly (Fig. 19) with PVC glue. After assembly, firmly
press the Float Switch into the Trap Assembly.
7. The provided 3/4-in. PVC tube may be replaced with up to
24-in. of 3/4-in. PVC tube to allow for float switch tee to
extend past the furnace casing for easier service.
IMPORTANT: using a longer PVC tube to extend the float
switch is not allowed when the trap itself is installed in the
Remote Trap configuration.
WARNING
!
CARBON
MONOXIDE
PROPERTY DAMAGE HAZARD
Failure to follow this warning could result in property
damage, personal injury or death.
PVC trap components must be properly glued using PVC
glue. CPVC components must be properly glued using
CPVC glue.
CVPC
Elbows
Fig. 16 - - Upflow Condensate Drain
14
A190323
POISONING
AND
Tube 1
Tube 2
Plastic Collar
& Gasket
Upflow Drain
Bracket
A190324
Specifications subject to change without notice.
Upflow Drain
Bracket
Fig. 17 - - Upflow - - Offset of Condensate Drain
Upflow Specific Steps – Standard Installation
1. Install and tighten remaining two (2) clamps and short
CPVC tubes (Fig. 15). The longer tube (Tube A) should be
installed in the upper most rubber elbow. Torque the clamps
to hand- -tight (15 lb- -in.). Over tightening hose clamps may
crack plastic components which may result in water leaks
and possibly water damage.
2. Remove adhesive backing from the Collar Gasket and apply
it to the rear side of the Collar Plate.
3. Place Collar Plate on over condensate drain knockout while
routing the short CPVC tubes through the Collar Plate.
4. Using four (4) of the sheet metal screws, screw the Plastic
Collar to the furnace casing through the four (4) holes in the
middle and top.
5. Install the Upflow Drain Bracket with two (2) sheet metal
screws to the bottom of the Collar Plate.
6. Assemble the two (2) E Tubes and Elbows (90°) to Tubes A
& B (Fig. 16). Ensure the two long tubes are pointed
downward before glue is set.
7. Set the Trap Assembly on the arms of the bracket and tight-
en with the provided bolt and nut. Ensure the bottom of the
large Tee is resting on the bracket (Fig. 18).
Bracket Arms
Fig. 18 - - Bracket Arms
Plastic Collar
CVPC
& Gasket
Elbows
Tube A
Tube 2
Trap Assy
A190325
A190327
440 01 4601 01