CE TEST REPORT
13. CONDUCTED DISTURBANCES INDUCED BY RADIO-FREQUENCY FIELD
IMMUNITY TEST ( CS )
Pass
performance Criteria :
??
Basic Standard
??
Generic Standard
??
Input Voltage, Frequency
??
Level
??
Test Voltage
??
Frequency Range
??
Temperature
??
Relative Humidity
??
Test Date
??

13.1 TEST LEVEL

Level
1
2
3
x
NOTE - x is an open class.
This level can be specified in the product specification.

13.2 OPERATING CONDITION

Full system
SPORTON International Inc.
TEL : 886-2-2696-2468
FAX : 886-2-2696-2255
A
:
EN 61 000-4-6 (1996)
:
EN 55 024 :1998
:
AC 230V, 50Hz
:
2
:
3 V/rms ( Modulated, 1KHz, 80%, AM )
:
0.15 MHz to 80 MHz
:
21° C
:
53 %
:
Feb. 16, 2001
Voltage Level ( EMF ),
1 V
3 V
10 V
Specified
Report No. : C121401
Page Number
: 51 of 62
Issued Date
: Feb. 21, 2001