CE TEST REPORT
9.5.2 Test Result of Contact Discharge
Polarity
Horizontal(At Front)
Horizontal (At Left)
Horizontal (At Right)
Horizontal (At Rear)
Vertical (At Front)
Vertical (At Left)
Vertical (At Right)
Vertical (At Rear)
Test Engineer :
SPORTON International Inc.
TEL : 886-2-2696-2468
FAX : 886-2-2696-2255
?2 / ?4 KV
?2 / ?4 KV
?2 / ?4 KV
?2 / ?4 KV
?2 / ?4 KV
?2 / ?4 KV
?2 / ?4 KV
?2 / ?4 KV
ROXY CHOU
Voltage
Tested No.
BY 25
BY 25
BY 25
BY 25
BY 25
BY 25
BY 25
BY 25
Report No. : C121401
Observation
Result
NORMAL
PASS
NORMAL
PASS
NORMAL
PASS
NORMAL
PASS
NORMAL
PASS
NORMAL
PASS
NORMAL
PASS
NORMAL
PASS
Page Number
: 37 of 62