Rinnai AH083CP Installation And Operation Manual page 6

Hydronic, with/without internal circulation pump

Advertisement

When transporting components of the hydronic
air handler, follow the guidelines below:
• Choose the correct hand truck to support
the weight and size of the system
components. Refer to section "3.8
Specifications" for specific weights and
dimensions.
• Use safe lifting and material handling
principles to prevent workplace accidents.
• Use proper lifting techniques to load the
equipment onto a hand truck.
• Position the equipment onto the hand
truck so the weight is evenly balanced.
• Use personal protective equipment, such
as gloves and steel-toed boots.
If storing components of the hydronic air
handler, follow the guidelines below:
• Store system components in a clean, dry
environment.
• Components must be protected from
direct sunlight.
• Do not store components outdoors.
• If transported or stored at temperatures
below 32°F (0°C), the components must
be warmed up to 60°F (15°C) before the
start of assembly.
• All components must be stored in the
original packaging.
6
Example:
AH083CP
AH 08
3
Series
AH Series
Hydronic Air Handler Installation and Operation Manual
C
P
Blower Motor
P = 3-Speed
PSC Motor
Circulating Pump
C = Circulation Pump
Included
(Model numbers without a
"C" do not include an
internal circulation pump)
Nominal Heating Capacity
at 140° F
3 = 30,000 BTU
4 = 40,000 BTU
5 = 50,000 BTU
6 = 60,000 BTU
Size / Air Flow
08 = 800 CFM
12 = 1,200 CFM
16 = 1,600 CFM
20 = 2,000 CFM