INVERTER SETTINGS
2.1

Names of the Parts on the Operation Panel

Inverter parameter settings and error content can be checked on the operation panel.
*: The operation panel cannot be removed from the inverter.
No.
Name
[1]
Monitor (4-digit LED)
[2]
Unit indication
[3]
Inverter operation mode LEDs
Operation panel status LEDs
PLC function LED
Operating status LED
Controlled motor type LED
[4]
PU/EXT key
[5]
MODE key
[6]
RUN key
[7]
SET key
[8]
STOP/RESET key
[9]
UP/DOWN key ( key)
[10]
Operation status LEDs
For details on the FR-E800-E operation panel, refer to the following.
Section 2.1 Operation panel in the FR-E800 Instruction Manual (Function)
For details on the FR-A800-E/F800-E operation panel, refer to the following.
Page 55 Operation panel
[4]
Description
Shows a numeric value (readout) of a monitor item such as the frequency and a parameter number.
Hz: ON when the actual frequency is monitored. (Blinks when the set frequency is monitored.)
A: ON when the current is monitored.
(Both "Hz" and "A" are OFF to indicate a value other than the frequency or the current.)
PU
ON when the inverter is in the PU operation mode.
EXT
ON when the inverter is in the External operation mode. (Lit at power-ON at initial setting.)
NET
ON when the inverter is in the Network operation mode.
MON
ON or blinks only when the first, second, or third monitor is displayed.
PRM
Lit to indicate parameter setting mode. The LED blinks when the inverter is in the easy setting mode.
P.RUN
ON when the PLC function of the inverter is valid.
RUN
ON or blinks during inverter running.
ON: During forward rotation operation.
Blinks slowly (1.4-second cycle): During reverse rotation operation.
Blinks quickly (0.2-second cycle): Operation is disabled although the start command is given.
PM
ON when the inverter is set to control the PM motor. The LED blinks during test operation.
Switches between the PU operation mode, the PUJOG operation mode, and the External operation mode.
Switches the operation panel to a different mode.
Executes a start command.
Confirms each selection. When this key is pressed during the monitor mode, the monitor item changes.
Stops the operation commands. Resets the inverter when the protective function is activated.
Changes the frequency and parameter settings.
NS
Shows communication status.
MS
Shows inverter status.
LINK1
Shows connector for communication (PORT1) status.
LINK2
Shows connector for communication (PORT2) status.
[1]
[2]
[5]
[6]
[7]
[8]
2.1 Names of the Parts on the Operation Panel
[3]
[10]
[9]
2 INVERTER SETTINGS
2
8