Furuno FCV-1200L Service Manual page 29

Color lcd sounder
Hide thumbs Also See for FCV-1200L:
Table of Contents

Advertisement

Adjuster
Adj.
R38
Adjusts offset voltage of A/D converter (H)
R39
Adjusts reference voltage of A/D converter (H)
R41
Adjusts offset voltage of A/D converter (L)
R42
Adjusts reference voltage of A/D converter (L)
R47
REC OUT (L) signal level adjuster
R49
REC OUT (H) signal level adjuster
Dip-switch
S1
Factory Setting
#1
OFF (linear)
#2
OFF (linear)
#3
OFF (linear)
#4
OFF (linear)
Note: The Log. position are used only when signals are exchanged between one and another FCV-1200L.
LED
LED
Name
CR5
Time of 1sec
EXIF 2 Board (02P6279)
R54
R57
CR15
Adjuster
Adj.
R2
Adjusts output signal level of "SIG OUT H"
R6
Adjusts output signal level of "SIG OUT L"
R29
Adjusts input signal level of "SIG IN AC-H"
R35
Adjusts input signal level of "SIG IN AC-L"
R54
Adjusts offset voltage of "SIG IN AC-H"
R57
Adjusts offset voltage of "SIG IN AC-L"
LED
LED
Name
CR15
Vcc
Remarks
Name
D/A (L) Log/linear
D/A (H) Log/linear
A/D (L) Log/linear
A/D (H) Log/linear
Always blinks
R35
Figure 4.10 Front View of EXIF 2 board (02P6279)
Remark
Always ON
Selects output signal (L) format either Log or linear
Selects output signal (H) format either Log or linear
Selects input signal (L) format either Log or linear
Selects input signal (H) format either Log or linear
Function
R29
TP1
Function
26
Function
R2
R6

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fcv-1200lm

Table of Contents