Error Messages - Newco Fresh Cup Manual

Single serving automatic pod machine
Table of Contents

Advertisement

ELECTRICAL COMPONENTS CONT'D
ITEM #
NEWCO PN
1
2
3
4
5

ERROR MESSAGES

Message - "THERMISTOR ERROR"
THERMISTOR IS OPEN OR SHORTED-REPLACE PN
Message - "HIGH TEMP ERROR"
RAPID TEMPERATURE RISE-HEATER ON WITH LOW WATER LEVEL-
CHECK FILL VALVE OR WATER SUPPLY LINE
Message - "UPPER/LOWER MOTOR ERROR"
BREW CHAMBER DRIVE MOTOR ERROR-CHECK FOR JAM OR
OBSTRUCTION IN BREW CHAMBER
Message - "BOARD ERROR"
CONTROL BOARD WRITE ERROR-REPLACE BOARD IF MESSAGE
DOES NOT CLEAR PN 780225
Message - "FILL TIMEOUT ERROR"
WATER NOT REACHING LEVEL PROBE-CHECK WATER SUPPLY OR
CHECK FOR WATER LEAK
Message - "HEATER TIMEOUT ERROR"
WATER NOT HEATED DURING TIMEOUT PERIOD-CHECK HEATER
RELAY PN
110958
704161-10 (1400W CANADA) OR HI-LIMIT THERMOSTAT PN
DESCRIPTION
780225
CONTROL BOARD
110626
SWITCH, DPST, ON/OFF
102383
SOLENOID FILL VALVE
105115
TRANSFORMER 120VAC-24VAC
780224
DISPLAY BOARD
OR HEATING ELEMENT PN 704166-10(1700W US) OR
18
QTY/EA
151677
111593
1
1
1
1
1