GPH16 "M" Series with R-410A
Self-Contained Package Heat Pump Units
Installation Instructions
Only personnel that have been trained to install, adjust, service or
repair(hereinafter, "service") the equipment specified in this manual
should service the equipment. The manufacturer will not be responsible
for any injury or property damage arising from improper service or service
procedures. If you service this unit, you assume responsibility for any
injury or property damage which may result. In addition, in jurisdictions
that require one or more licenses to service the equipment specified in
this manual, only licensed personnel should servise the equipment.
Improper installation, adjustment, servicing or repair of the equipment
specified in this manual, or attempting to install, adjust, service or repair
the equipment specified in this manual without proper training may result
in product damage, property damage, personal injury or death.
IOG-3018C
01/20
WARNING
Our continuing commitment to quality products may mean a change in specifications without notice.
Goodman Manufacturing Company, L.P.
19001 Kermier Rd. Waller, Tx 77484
© 2015 - 2020 Goodman Manufacturing Company, L.P.
Replacement Parts..........................................................2
Safety Instructions........................................................2
General Information.......................................................3
Unit Location....................................................................4
Clearances.......................................................................5
Roof Curb Post-Installation Checks..........................5
Roof Top Duct Connections..........................................5
Rigging Details.................................................................6
Electrical Wiring............................................................7
Circulating Air And Filters...........................................9
Condensate Drain Connection......................................9
Startup, Adjustments, And Checks............................10
Air Flow Adjustments...................................................11
Heat Pump Operation.....................................................13
Maintenance...................................................................14
Appendix B Electrical Data........................................17
Appendix C Unit Dimensions.........................................18
Wiring Diagrams............................................................20
Start-Up Checklist.........................................................21
www.goodmanmfg.com
INDEX
PROP 65 WARNING
FOR CALIFORNIA CONSUMERS
WARNING
Cancer and Reproductive Harm -
www.P65Warnings.ca.gov
.....16
0140M00517-A

Advertisement

Table of Contents
loading

Summary of Contents for Goodman GPH16 M Series

  • Page 1: Table Of Contents

    Our continuing commitment to quality products may mean a change in specifications without notice. Goodman Manufacturing Company, L.P. 19001 Kermier Rd. Waller, Tx 77484 IOG-3018C www.goodmanmfg.com 01/20 © 2015 - 2020 Goodman Manufacturing Company, L.P.
  • Page 2: Replacement Parts

    HOMEOWNER SUPPORT WARNING GOODMAN COMPANY, L.P. 19001 KERMIER ROAD This unit must not be used as a “construction WALLER, TEXAS 77484 heater” during the finishing phases of 877-254-4729 construction on a new structure.
  • Page 3: General Information

    Specification sheets can be found at refrigeration tonnage, heating output and voltage. www.goodmanmfg.com for Goodman brand products. Within the website, please select the products menu and Carefully inspect the unit for damage including damage then select the submenu for the type of product to be to the cabinetry.
  • Page 4: Unit Location

    UNIT LOCATION Roof top Installations Only: • To avoid possible property damage or personal injury, the roof must have sufficient structural WARNING strength to carry the weight of the unit(s) and snow or water loads as required by local codes. Consult a structural engineer to determine the weight To prevent possible equipment damage, property capabilities of the roof.
  • Page 5: Clearances

    • Sufficient structural support must be determined prior Adequate clearance around the unit should be kept for to locating and mounting the curb and package unit. safety, service, maintenance, and proper unit operation. A • Ductwork must be constructed using industry clearance of 48”...
  • Page 6: Rigging Details

    ROOF TOP DUCT CONNECTIONS Install all duct connections on the unit before placing the WARNING unit on rooftop. To prevent possible equipment damage, property Horizontal Discharge damage, personal injury or death, the following Refer to IOD-7082 included in the literature pack for bullet points must be observed when installing installing horizontal duct covers.
  • Page 7: Electrical Wiring

    ELECTRICAL WIRING CONDENSER COIL WARNING RETURN HIGH VOLTAGE! EVAPORATOR COIL Disconnect all power before servicing or installing this unit. Multiple power sources may be SUPPLY present. Failure to do so may cause property damage, personal injury or death. COMPRESSOR WARNING Corner and center of gravity locations Note: Unit should be lifted at a point above center HIGH VOLTAGE!
  • Page 8 Main power wiring should be sized for the minimum circuit ampacity shown on the unit’s database. Size wires in accordance with the ampacity tables in Article 310 of the National Electrical Code. If long wires are required, it may be necessary to increase the wire size to prevent excessive voltage drop.
  • Page 9: Circulating Air And Filters

    CIRCULATING AIR AND FILTERS HIGH VOLTAGE ENTRANCE (REMOVE PLUG) Ductwork The supply duct from the unit through a wall may be installed without clearance. However, minimum unit 19-3/8 clearances must be maintained (see “Clearances” section). The supply duct should be provided with an access panel 31-3/8 large enough to inspect the air chamber downstream of the heat exchanger.
  • Page 10: Startup, Adjustments, And Checks

    STARTUP, ADJUSTMENTS, AND CHECKS Temporary Heating Or Cooling If the unit is to be used for temporary heating or cooling, a “Startup, Adjustments, and Checks” must first be performed WARNING in accordance with this manual. Damage or repairs due to failure to comply with these requirements are not covered HIGH VOLTAGE! under the warranty.
  • Page 11: Air Flow Adjustments

    System Voltage - That nominal voltage value assigned Note: for proper operation Y2 and W2 should have a higher to a circuit or system for the purpose of designating its speed setting than the G, Y1 and W1 speed setting. voltage class.
  • Page 12 7. Check that the compressor is operating correctly. Note: If the outdoor ambient is above 80°F, the The scroll compressors in these units MUST operate unit may trip on its high pressure cut out when on in the proper rotation. To ensure the compressors heating.
  • Page 13: Heat Pump Operation

    HEAT PUMP OPERATION Heating When the heat pump is on the heating cycle, the outdoor coil is functioning as an evaporator. The temperature Cooling Cycle of the refrigerant in the outdoor coil must be below the When the heat pump is in the cooling cycle, it operates temperature of the outdoor air in order to extract heat from exactly as a Summer Air Conditioner unit.
  • Page 14: Maintenance

    MAINTENANCE Filters WARNING CAUTION HIGH VOLTAGE! To prevent property damage due to fire and Disconnect all power before loss of equipment efficiency or equipment servicing or installing this unit. damage due to dust and lint build up on internal Multiple power sources may be parts, never operate unit without an air filter present.
  • Page 15 Wiring Example Electric Heat Wiring Example...
  • Page 16: Appendix A Blower Performance Tables - Heat Pump

    APPENDIX A BLOWER PERFORMANCE TABLES - HEAT PUMP 5 Ton Heat Pump Standard Static Drive Models: GPH1660M Horizontal Flow Down Flow External External Speed Static Speed Static SCFM SCFM Pressure Pressure (ESP), in w.c. (ESP), in w.c. 1299 614 0.16 1326 653 0.22 1209 674...
  • Page 17: Appendix B Electrical Data

    APPENDIX B ELECTRICAL DATA Outdoor Fan Optional Powered Optional Model Electrical Compressor Indoor Fan Motor Optional Electric Heat Power Supply Motor Convienience Power Number Rating QTY RLA LRA QTY HP FLA Type HP FLA Part # Outlet FLA Exhaust FLA 44.1/44.1 70.0/70.0 7.2/6.5 51.3/50.6 70.0/70.0...
  • Page 18: Appendix C Unit Dimensions

    APPENDIX C UNIT DIMENSIONS 73-3/8" 47-5/8" "A" 74" 48-5/16" Model Dim. "A" 5 Ton Heat Pump 43-1/2" 19-1/2 RETURN 5-5/16 11” X 25” EMBOSS DRAIN 5-7/8 THRU THRU CURB BASE LOCATION SUPPLY UTILITIES 12” X 17” 27-3/4 7-3/8 RETURN 4-1/2 11"...
  • Page 19: Appendix D Air Flow For Electric Heat

    APPENDIX D AIR FLOW FOR ELECTRIC HEAT HEATER KIT MODEL NUMBER NOMENCLATURE HEATER KIT MINIMUM MAXIMUM UNIT MODEL NUMBER SCFM SCFM 6, 7 EH*-*S05 1500 EH*-*S10 1500 GPH1660M 2500 Electric EH*-*S15 1500 EH*-*S20 1550 Heater Heater Type Staged SCR (modulating) Voltage 208-230/1/60 Single phase 60 Hz...
  • Page 20: Wiring Diagrams

    WIRING DIAGRAMS Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.
  • Page 23 THIS PAGE IS INTENTIONALLY LEFT BLANK...
  • Page 24 Product Registration page. Our continuing commitment to quality products may mean a change in specifications without notice. Goodman Manufacturing Company, L.P. 19001 Kermier Rd. Waller, Tx 77484 www.goodmanmfg.com © 2015 - 2020 Goodman Manufacturing Company, L.P.

This manual is also suitable for:

Gph1660m

Table of Contents