1-4-4 Warm air blowing section (Multi purpose feeder only)
(1) Detaching and refitting the PF heater PWB
Procedure
1. Remove the cassette.
2. Remove two screws.
3. Insert a flat-blade screwdriver into the
cutout and release two hooks.
4. Turn the paper feeder with the bottom
side up.
5. Release two hooks and then remove
the fan cover.
Hole
Hook
Screw
Figure 1-4-11
Hook
Hook
Figure 1-4-12
1-4-8
Hole
Screw
Fan cover
3M9/3NA
Hook