LED

STATUS LED
The STATUS LED goes on green when the Switch Module operates normally. When the LED is lit or flashing in
amber, it indicates that the Switch Module has failed. The following table lists indications of the STATUS LED,
descriptions, and actions to take. If an error occurs, contact your service representative.
STATUS LED
On (Green)
Off
Flash (Amber)
ID LED
The ID LED is intended to identify a specific Switch Module in the Blade Enclosure when more than one Switch
Modules are installed. Making this LED being lit can help the maintenance work to identify the faulty device.
When the recognized command is received from the management software such as NEC ESMPRO/Server
Manager, the LED goes on or flashes in blue.
ID LED
On or Flash in blue
Off
Description
The Switch Module is operating
normally.
The power is turned off.
The following errors have been
detected.
- Abnormal temperature
- Processor error or other
components error
Switch Module interface
mismatch
Management software has specified the Switch Module.
Other than the above
Action
-
Turn on the power.
When installed in the Blade Enclosure, an error
message is displayed on the SIGMABLADE
monitor.
Refer to the User's Guide of the EM Card.
When installed in the Blade Enclosure, "SWMn
Ifmiss Alm" (n: slot number) is displayed on the
SIGMABLADE monitor. Make sure the location
of the Mezzanine Card in the CPU Blade and
the Switch Module.
Refer to the User's Guide of the Blade
Enclosure.