Vaillant VED E 8 INT Series Operating Instructions Manual page 47

Table of Contents

Advertisement

Nominal capacity
Domestic hot and cold
water connection,
boiler side
Unit dimensions,
width
Unit dimensions,
height
Unit dimensions,
depth
Weight when filled,
approx.
IP rating
Technical data – Domestic hot water mode
Max. permissible inlet
temperature, Tin max.
Minimum start-up
pressure
Minimum start-up flow 3 l/min
Switch-off water
volume
Max. flow rate quantity 8 l/min
Max. flow rate quantity
with limiter 12 l
Permitted excess
pressure
Technical data – Electrics
Rated voltage
Nominal output
Nominal current
Fuse protection
Specific resistance
ρ15 ≥ (when ϑ cold ≤
35 °C)
Specific conductivity
σ15 ≤ (when ϑ cold ≤
35 °C)
Electrical connection
0020288451_00 electronicVED Installation instructions
VED E 18/8 INT VED E 21/8 INT VED E 24/8 INT VED E
0.4 l
0.4 l
G 1/2"
G 1/2"
240 mm
240 mm
481 mm
481 mm
100 mm
100 mm
4.4 kg
4.4 kg
IP 25
IP 25
VED E 18/8 INT VED E 21/8 INT VED E 24/8 INT VED E
55 ℃
55 ℃
0.015 MPa
0.015 MPa
3 l/min
2.5 l/min
2.5 l/min
8 l/min
12 l/min
12 l/min
1.0 MPa
1.0 MPa
VED E 18/8 INT VED E 21/8 INT VED E 24/8 INT VED E
400 V
400 V
18 kW
21 kW
26 A
31 A
32 A
32 A
≥ 900 Ω⋅cm
≥ 900 Ω⋅cm
≤ 1,111.0 µS/cm ≤ 1,111.0 µS/cm ≤ 1,111.0 µS/cm ≤ 1,111.0 µS/cm
3~PE,
3~PE,
400 V/50 Hz
400 V/50 Hz
Appendix
27/8 INT
0.4 l
0.4 l
G 1/2"
G 1/2"
240 mm
240 mm
481 mm
481 mm
100 mm
100 mm
4.4 kg
4.4 kg
IP 25
IP 25
27/8 INT
55 ℃
25 ℃
0.015 MPa
0.015 MPa
3 l/min
3 l/min
2.5 l/min
2.5 l/min
8 l/min
10 l/min
12 l/min
12 l/min
1.0 MPa
1.0 MPa
27/8 INT
400 V
400 V
24 kW
27 kW
35 A
39 A
40 A
40 A
≥ 900 Ω⋅cm
≥ 900 Ω⋅cm
3~PE,
3~PE,
400 V/50 Hz
400 V/50 Hz
45

Hide quick links: