Bubble massage bath, include electronic drain and soft touch panel.

Advertisement

8. Manual purge cycle does
not work.
9. Massage pillow does not
work.
10. Cannot operate or stop
electronic drain.
11. The bath cannot overflow.
12. Water level cannot be
maintained after the bath
is filled with water.
13. Water temperature cannot
be shown.
14. Abnormity shown of water
emperature.
1200098
-T01-B
A. User keypad cable loose or damaged.
B. User keypad does not work.
C. Blower motor does not work.
D. Controller dose not work.
A. Malfunction of mechanism.
B. Malfunction of power supply.
A. User keypad trips.
B. Controller trips.
C. Electronic drain mechanism
work
.
A. Water level sensor trips.
B.
Electronic drain mechanism does not
work
.
A. Water level protector functions.
B. Water level surpasses overflow level.
C. Overflow level is not correct.
A. User keypad cable trips.
B. User keypad trips.
A. Temperature sensor of electronic drain
mechanism does not work.
A. Check wire connections. If necessary,
replace user keypad.
B. Replace user keypad.
C. Replace blower motor.
D. Replace the controller.
A. Replace massage pillow.
B. Replace power supply.
A. Replace user keypad.
B. Replace controller.
does not
C. Replace electronic drain mechanism.
A. Replace water level sensor.
B. Replace electronic drain mechanism.
A. Lower the water level in the bath.
B. Lower the water level in the bath.
C. Contact customer service personnel of
Kohler to readjust the water level.
A. Check wire connections, or replace
user keypad.
B. Replace user keypad.
A. Replace electronic drain mechanism.