12 Technical data

1
Type and order code
2
Design
2.1
Defrosting
2.2
Nominal cylinder volume
2.3
Transfer area of the internal heat exchanger
2.4
Sensor pipe ø
for external sensors
internal
2.5
Installation location
2.6
Cylinder material
2.7
Cylinder insulation
2.8
Nominal cylinder pressure
3
Operating limits
3.1
Heat source operating limit
3.2
Domestic hot water setting range in heat pump operation
4
Flow / sound
4.1
Air flow level I II III
4.2
External compression, level III
4.3
Sound power level I / II / III
4.4
Sound pressure level I / II / III
5
Dimension/weight and filling quantities
5.1
Dimensions height (max.) x cross-section (max.)
5.2
Air duct connection diameter
5.3
Weight (empty)
5.4
Refrigerant R 134a/total filling weight
5.5
GWP value / CO
equivalent
2
5.6
Refrigeration circuit hermetically sealed
6
Electrical connection
6.1
Degree of protection
6.2
Connection voltage
6.3
Connecting cable approx. 2.7 m - 1.5 mm
6.4
Fuse max.
6.5
Power consumption heat pump cos
6.6
Supplementary electrical heating power consumption
6.7
Power consumption max.
6.8
Heat pump nominal power consumption at 45 °C
6.9
Supplementary electrical heating power consumption
6.10 Total power consumption max.
7
Hydraulic connection
7.1
Circulation pipe connection
7.2
Domestic hot water outlet connection
7.3
Cold water inlet connection
7.4
Internal heat exchanger connection
8
Performance values
8.1
Heating-up period from 15 °C to 45 °C
8.2
Mean heat output at 45 °C
8.3
COP (t) complying with EN 255 at 45 °C
3
8.4
Stand loss in 24h
1. At a distance of 1m (free-standing installation or installation without exhaust air duct or 90° pipe bends on outlet side).
2. Air intake temperature of 20 °C and relat. humidity of 70 %
3. Room temperature 20 °C (heat pump operation)
EN-12
1
2
2
2
2
451903.66.17 · FD 9908
litre
2
m
mm
bar
°C
°C
3
m
/h
Pa
dB(A)
dB(A)
mm
mm
kg
(kg)
--- / t
A
A
A
A
W
W
W
external thread
external thread
external thread
external thread
h
W
W
LWP 200E
LWP 200E
No
200
-
-
Frost-free
Enamelled steel complying with DIN 4753
PU with foil cladding
10
15 to 35
± 1.0 K
23 to 60
60, 90, 140
120
46.7 / 54.4 / 64.5
36.8 / 45.3 / 55.9
1700 x 550
125
85
1.0
1430 / 1
yes
IP 21
1/N/PE~230 V, 50 Hz
With plug
C16
0.8
6.5
8.7
253
1500
1900
-
R 3/4"
R 3/4"
-
7.6
910
3.4
1.13