ELECTRICAL CONNECTION

WARNING: ELECTRICAL AND GROUNDING
CONNECTIONS MUST COMPLY
WITH APPLICABLE PORTIONS
OF THE NATIONAL ELECTRICAL
CODE AND/OR OTHER LOCAL
ELECTRICAL CODES.
Total
Volts
Hz
KW
8.5
208
50/60
8.5
240
50/60
8.5
208
50/60
8.5
240
50/60
8.5
480
50/60
9.25
208
50/60
9.25
240
50/60
9.25
208
50/60
9.25
240
50/60
9.25
480
50/60
15
208
50/60
15
240
50/60
15
208
50/60
15
240
50/60
15
480
50/60
15.75
208
50/60
15.75
240
50/60
15.75
208
50/60
15.75
240
50/60
15.75
480
50/60
2002 National Electric Code
*Dual Element Time-Delay Fuse or Inverse Time Circuit Breaker
Circuit Size (minimum) & Fuse/Circuit Breaker Size (maximum) compiled in accordance with the
National Electrical Code (ANSI/NFPA 70), 2002 Edition.
Ph
KW Per Phase
L1-L2
L2-L3
L3-L1
1
1
3
4.25
2.12
3
2.83
2.83
3
2.83
2.83
1
1
3
4.25
2.69
3
2.83
3.58
3
2.83
3.58
1
1
3
7.50
3.75
3
5.00
5.00
3
5.00
5.00
1
1
3
7.50
4.31
3
5.00
5.75
3
5.00
5.75
C24EA SERIES ELECTRIC COUNTER CONVECTION STEAMERS
The wiring diagram is located on the right side
panel as you face the steamer. This steamer is
hard wired.
Rated Amps
3-Phase Amps Per Line Single
L1
L2
2.12
26.54
26.54
2.83
20.50
20.50
2.83
10.30
10.30
2.12
26.54
28.88
2.83
20.45
23.15
2.83
10.21
11.57
3.75
46.84
46.84
5.00
36.08
36.08
5.00
18.04
18.04
3.75
46.84
49.18
5.00
36.08
38.79
5.00
18.04
19.40
— 7 —
Circuit
Size
Phase Amps
L3
Circuit
Breaker
(Amps)
40.87
60
35.42
50
17.70
35
20.50
30
10.30
15
43.57
60
38.54
50
20.04
35
23.15
30
11.57
15
72.12
90
62.50
75
31.23
60
36.08
50
18.04
25
74.82
90
65.63
80
33.57
60
38.79
50
19.40
25
Fuse
90°C
Size
Copper
or
Min.
Wire
Size
Size*
60
8
50
8
35
10
25
10
15
16
60
6
50
8
35
10
30
10
15
16
90
4
75
6
60
6
50
8
25
14
90
4
80
4
60
6
50
8
25
14