file to be downloaded is under the TFTP root directory and the cable is connected
properly.
Fault 3
Start the Router, upgrade the software with the TFTP approach, and the system
displays the following prompt:
DownLoad Program To Flash Through Net Port
boot device
unit number
processor number
file name
inet on ethernet (e) : 1.1.1.1
host inet (h)
user (u)
ftp password (pw)
flags (f)
Attached TCP/IP interface to wancom0.
Attaching network interface lo0... done.
Loading... tftpGet: Error occurred while transferring the file.
A bad file or twisted pair doesn't link correctly!Loading Failed
Troubleshooting
The problem occurs because the IP address of the computer is not correctly
configured. To solve the problem, make a correct configuration of the IP address.
Fault 4
Start the Router, upgrade the software with the TFTP approach, and the system
displays the following prompt:
DownLoad Program To Flash Through Net Port
boot device
unit number
processor number
file name
inet on ethernet (e) : 1.1.1.1
host inet (h)
user (u)
ftp password (pw)
flags (f)
Loading... Done
1000 Bytes Downloaded.Crc Error!
Troubleshooting
The problem occurs because the downloaded file is not the application of 6000
Router. To solve the problem, specify a correct application.
Bar code labels display product and maintenance information on the router chassis
and FIC.
Troubleshooting Application Software Upgrade
: wancom
: 0
: 0
: 6000.bin
: 1.1.1.3
: user
: password
: 0x80
: wancom
: 0
: 0
: 6000.bin
: 1.1.1.2
: user
: password
: 0x80