Replacing The Power Supply - Bosch DIVAR IP all-in-one 7000 3U Installation Manual

Hide thumbs Also See for DIVAR IP all-in-one 7000 3U:
Table of Contents

Advertisement

44
en | Maintenance
4.
5.
6.
7.
9.14

Replacing the power supply

Warning!
Redundant power supplies
!
This unit might have more than one power supply connection. To de-energize the unit, remove
all connections.
LED status:
The power supply can be replaced without turning off the system if a redundant power supply
is available.
Replacement units can be ordered directly from Bosch RMA desk.
To replace the power supply:
1.
2020.04 | V1.1 | DOC
Press the fan release tab to lift the failed fan from the chassis and pull it completely from
the chassis.
1
2
1 - Release tab
2 - Airflow direction indicator
Place the new fan into the vacant space in the housing while making sure the arrows on
the top of the fan (indicating the airflow direction) point in the same direction as the
arrows on the other fans.
Reconnect the power cord, turn on the system and make sure that the fan is working
properly before replacing the chassis cover.
Replace the chassis cover.
Amber lighted LED: The power supply is off.
Green lighted LED: The power supply is operating.
Unplug the AC power cord of the failed power supply.
Installation manual
DIVAR IP all-in-one 7000 (3U)
Bosch Security Systems B.V.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dip‑72g0‑00nDip‑72g8‑16hdDip‑72gc‑16hd

Table of Contents