Configuring The T1-2R With Talk-Around Option Kit - Motorola ASTRO 25 GTR 8000 Manual

Base radio
Hide thumbs Also See for ASTRO 25 GTR 8000:
Table of Contents

Advertisement

d At the confirmation screen, click OK.
e Click Change to Normal Mode.
The device halts activity in the current mode and switches operation to the requested mode.
f
Disconnect the Ethernet cable from the transceiver module Ethernet service port.
g Repeat for each device in the configuration.
A.2.4

Configuring the T1-2R with Talk-Around Option Kit

Prerequisites: Ensure that all required installation procedures have been performed for the base radio
and receiver and that the devices have been powered up.
When and where to use: This procedure is used to configure the WildCard Tables for a T1-2R with
Talk-Around configuration using the Configuration/Service Software (CSS).
Procedure:
1 If necessary, perform the initial configuration for the base radio. See
CSS on page
134for details.
2 Connect to the Ethernet port on the base radio. See
on page 140
for details.
3 From the menu, select File → Read Configuration From the Device.
4 From the navigation pane, select Hardware Configuration. Set Station Type [R] to Analog
Only.
NOTICE: When configuring GPW 8000 Receivers, the Hardware Platform [R]
parameter is set to GPW 8000 Satellite Receiver.
5 Set Antenna Relay [R] to Enabled.
NOTICE: Use the default value of 30 msec for the Antenna Relay Delay.
6 From the navigation pane, select WildCard Tables. Click Set to Default to add default
WildCard tables.
7 Click Yes to reset the WildCard Tables to their default structure. The following default WildCard
Tables are created:
NOTICE: WildCard Table numbers are arbitrary and shown for illustration purposes.
Memory size and the number of States and Commands in each table limit the maximum
number of WildCard tables.
Wild-
Descrip-
Card
tion
Table
1
In-cabi-
net RPT
2
Rx In-
hibit
Appendix A: Conventional GTR 8000 Base Radio Option Kits
States and Condi-
tion
State
Value
Input 6
n/a
Input 7
n/a
Device Configuration in
Connecting Through an Ethernet Port Link
Actions
Com-
Value
mand
In-cabi-
n/a
net Re-
peat ON
RX IN-
n/a
HIBIT
MN003286A01-E
Inactions
Com-
Value
mand
In-Cabi-
n/a
net Re-
peat
OFF
RX EN-
n/a
ABLE
299

Advertisement

Table of Contents
loading

Table of Contents