Download Print this page

General Installation Steps - Daikin ONE Installation & Operation Manual

Powered

Advertisement

Ventilator Accessories
The capabilities of the Daikin One Powered Ventilator can be
enhanced by adding any of the following optional accessories
(sold separately):
Heater (70 CFM & Higher)
Motorized Damper kit
Air Intake Hood
Installation
i
WARNING!
To reduce the risk of fire, electric shock and injury to
person, observe the following:
1. Use this unit only in the manner intended by the
manufacturer. If you have questions, contact Daikin.
2. Before servicing or cleaning the unit, switch power off at
service panel and lock the service disconnecting means to
prevent power from being switched on accidentally.
When the service disconnecting means cannot be locked,
securely fasten a prominent warning device, such as a tag,
to the service panel.
3. Installation work and electrical wiring must be done by
qualified person(s) in accordance with all applicable codes
and standards, including fire-related construction.
4. When cutting or drilling into a wall or ceiling, do not damage
electrical wiring or other hidden utilities.
5. To avoid motor bearing damage and noisy and/or
unbalanced impellers, keep drywall spray, construction
dust, etc. off power unit.
6. Read all instructions before installing or using ventilator.
7. For residential installations only.
8. Must use suitable air intake hood with insect screen to
protect air intake.
i
WARNING!
For general ventilating use only. Do not use for exhausting
hazardous or explosive materials and vapors.
i
WARNING!
Do not use this ventilator with any solid-state speed
control device.
i
CAUTION!
Do not use in kitchens.
i
CAUTION!
The ducting from this ventilator to the outside of the building
has a significant effect on the airflow, noise and energy con-
sumption of the ventilator. Use the shortest, straightest duct
routing possible between the ventilator and the home's exte-
rior for best performance, and avoid installing the ventilator
with smaller ducts than recommended. Insulation around the
ducts can reduce energy loss and help inhibit mold growth.
Ventilators installed with existing ducts may not achieve their
rated airflow.
Daikin North America LLC reserves the right to discontinue or change at any time, specifications or designs without notice or without incurring
obligations. Performance of the Ventilator and/or Accessories will depend on house plan design, duct design and heating/cooling equipment
IO-DPV
DQ-P-70-AH-H
DQ-P-MDV
DQ-P-AIH
www.daikincomfort.com

General Installation Steps

i
CAUTION!
Make sure power is switched off at service panel before
starting installation.
Preparing the Ventilator
1. Unpack ventilator from the carton and confirm that
all pieces are present. In addition to the ventilator you
should have:
2 - Collar Assemblies (attached at factory)
2 - Mounting Brackets (attached at factory)
1 - Controller (attached at factory)
1 - Installation and Operation Manual
2. Choose the location for your ventilator. This ventilator will
require at least 12" of clearance from the ceiling or wall
to access the control compartment. It can be mounted
using the mounting brackets provided or can be surface
mounted to a wall or ceiling. To ensure the best air and
sound performance, it is recommended that:
− The length of ducting and the number of elbows should
be kept to a minimum,
− The radius of each elbow should be as large as possible
for the installation, and
− Insulated rigid duct should be used where possible.
NOTE: The ventilator must be installed in a location where
it can be easily accessed for service once installed.
3. No additional vibration deadening materials are needed
for this ventilator.
Mounting the Ventilator
1. Confirm that the ventilator is positioned so the airflow is in
the correct direction.
2. Mounting
a. Surface Mounting: Place the ventilator in a position so
that at least one of the mounting brackets is centered on
a stud or joist and mark the location for the four (4) holes
in the mounting brackets for securing the ventilator.
Remove the ventilator and install properly rated wall/
ceiling anchors for any of the holes that do not go
directly into a joist or stud. The ventilator weighs
approximately 15 pounds not including the duct work
attached to it. Position ventilator in place by securing
with screws (not included) through the four (4) holes in
the mounting brackets (Figure 1).
b. Mounting to a Joist: Install two, 2" x 4" headers (not
included) between the joists to support the ventilator.
Position the ventilator housing on the headers
and secure the mounting brackets with screws
(not included) to the headers (Figure 2).
c. Hanging Rods Mounting: Lift unit up onto the
threaded rods and secure in place using appropriate
hardware (not included). Threaded rods must each be
a minimum of 24" in length (Figure 3). The installation
shown in Figure 3 is upside down when installing to
the threaded rod
Installation
.
3

Advertisement

loading