Wiring the Ventilator
i
CAUTION!
Make sure power is switched off at service panel before
starting electrical work.
i
CAUTION!
Installation work and electrical wiring must be done by
qualified person(s) in accordance with all applicable codes and
standards, including fire-related construction.
Note: This unit includes a small, wiring compartment for
making electrical connections to the main power
1. Remove the wire compartment cover screw and set
aside the screw and cover in a secure place (Figure 5).
2. Pull the loose black, white and green wires out from the wire
compartment (additional wires will be present).
Install an approved cable connector to the hole in the wire
compartment cover (not included) to protect the wire from
being cut by the sharp metal of the hole in the cover. Run a black
(hot), white (neutral), and a green or bare ground wire from the
supply through the cable connector. Connect all wires
from the supply to their corresponding wires within the
wire compartment (Figure 6). Use approved methods for
all connections.
3. Carefully tuck wires back inside the wire compartment
and replace wire compartment cover securing it with the
screw that was removed earlier.
Figure 5 - Remove the wire compartment cover
Black
Neutral (White)
Green
Green
Figure 6
IO-DPV
Wire Compartment Cover
Black
Neutral (White)
Ground (Green or Bare)
www.daikincomfort.com
Setting the Ventilation Flowrate
1. Determine the CFM desired for ventilating the home. This unit
can be set to deliver between 40 CFM and 100 CFM of outdoor
air to the home in increments of 10 CFM.
2. Remove the screws securing the control compartment cover
(a) and remove the cover (b) to gain access (Figure 7).
Locate the speed control panel inside the unit.
3. Flowrate Selection
a. For flowrate of 40 CFM to 70 CFM: Push the toggle switch
DOWN towards the "LOWER CFM" speed dial, then set the
speed dial to the desired CFM (Figure 8).
b. For settings of 80 CFM to 100 CFM: Push the toggle switch
UP towards the "HIGHER CFM" speed dial, then set the speed
dial to the desired CFM (Figure 8).
Wire Compartment Cover
a) Remove screws
Figure 7 - Control Compartment Cover
Figure 8 - Speed Control Panel