ELECTRONICCONTROL SETUP INSTRUCTIONS
If cycle counter (90C) is selected, the following
is true:
1 00
Cycles in HUNDREDS
1 0__22
= 200
2 00
Cycles in ONES
2 2__5 = 25
TOTAL CYCLES= 225
This is "VIEW ONLY" and cannot be cleared.
• Press the PERM PRESSbutton once to advance to next code.
If money
counter
(I.0C
or I.C0)
is selected,
the following
is
true:
300
Dollars
in HUNDREDS
30:1 = _;100.00
400
Dollars
in ONES
46__8_8 = $ 68.00
500
Number
of CENTS
57__55 = ._ 00.75
TOTAL = ._168.75
END of SET-UP PROCEDURES
TO EXIT FROM SET-UP MODE
1. Close the service access door.
2. Disconnect dryer from power before reinstalling
the AA1
connector, if it was removed.
3. Remove the manual set-up card.
Diagnostic Codes
If the set-up mode is entered and one of the following
has
previously occurred, the appropriate
diagnostic code will be
in the display.
d5
Blocked coin 1 or coin drop UI control
circuit failure (coin recognition
and
customer display disabled while
blockage persists).
d 9
Voltage detected below 90 VAC for
8 seconds.
d 13
Blocked coin 2 or coin drop UI control
circuit failure (coin recognition
and
customer display disabled while
blockage persists).
d 16
Not receiving communications
from installed debit card reader in
Enhanced (Generation 2) Debit mode.
F 01
F 22
F 23
F 70
F71
F 73
F 74
Dryer motor
control
circuit
error
(cycles and price display
disabled
until
diagnostic
code is manually
cleared).
The control
doesn't
know
if the motor
relay is bad (stuck on), the motor
relay
drive
circuit
is bad (shorted),
causing
the motor
relay to stay on, or the
motor
relay feedback
circuit
is bad.
Exhaust thermistor
open, temperature
drops below 18°F (>50 kO) for 1
minute in Run mode, or immediately
in Factory Diagnostic Mode.
Exhaust thermistor
shorted,
temperature
above 250°F (<500Q) for
i minute in Run mode, or immediately
in Factory Diagnostic Mode.
UI is not receiving
communications
from
CCU (cycles and price display
disabled
while
error
persists
or is
manually
cleared).
CCU is not receiving
communications
from
UI (cycles and price display
disabled
while
error
persists
or is
manually
cleared).
UI Microprocessor
is not able to read
or verify
EEPROM (cycles and price
display
disabled
until
diagnostic
code
is manually
cleared).
UI EEPROM memory
is a CRC failure
(cycles and price display
disabled
until
diagnostic
code is manually
cleared).