Download Print this page

YASKAWA 1000 Series Installation Manual page 16

Ac drive, option, analog input
Hide thumbs Also See for 1000 Series:

Advertisement

5 Installation Procedure
5.
Prepare and connect the wire ends as shown in
Wire Gauges and Tightening Torques on page 20
tightening torque is applied to each terminal. Take particular precaution to ensure
that each wire is properly connected and wire insulation is not accidentally pinched
into electrical terminals.
WARNING! Fire Hazard. Tighten all terminal screws according to the specified tightening torque. Loose
electrical connections could result in death or serious injury by fire due to overheating electrical connections.
Tightening screws beyond the specified tightening torque may cause erroneous operation, damage the
terminal block, or cause a fire.
NOTICE: Heat shrink tubing or electrical tape may be required to ensure that cable shielding does not
contact other wiring. Insufficient insulation may cause a short circuit and damage the option or drive.
Figure 7
Figure 8
Preparing wire ends:
Pull back the shielding and lightly
twist the end with fingers, keeping
the ends from fraying.
16
Shield
Option terminal
FE
Figure 7 Preparing Ends of Shielded Cable
about 5.5 mm (7/32")
When not using
crimped insulated
sleeves
Figure 8 Preparing and Connecting Cable Wiring
YASKAWA ELECTRIC TOBP C730600 38C 1000-Series Option AI-A3 Installation Manual
Figure 7
Insulation
Customer-supplied
analog input signal
Shield sheath
(Insulate with electrical tape
or shrink tubing)
Screwdriver blade size
Blade depth of
0.4 mm or less
Blade width of
2.5 mm or less
Loosen the screws and
insert the wire into the
opening on the terminal block.
To customer circuit
(do not solder ends)
and
Figure
8. Refer to
to confirm that the proper
AI
AI
Option terminal block

Hide quick links:

Advertisement

loading

This manual is also suitable for:

A1000 seriesL1000a seriesAi-a3