Align the offset at the coupling between electrical machines and the driven machines so that the
maximum permissible vibration values according to ISO 10816-3 are not exceeded.
5.6.6
Axial and radial forces
You can obtain the permissible values for axial and radial forces by contacting the Service Center
or referring to the machine catalog.
1FU9
Operating Instructions, 07/2020, A5E46712792A
Assembly
5.6 Installing the machine
55