TABLE 7:
General System Settings (Continued)
Default
Name
Setting
Smart
Yes
Recovery
Fan On
No
with W
Indoor
Temp
Offset
Indoor Hum
0%
Offset
Auto
Change-
30 MIN
over
Remote
None
Sensor
Cool
OFF
Lockout
Time
Between
15 MIN
Fuel Types
Johnson Controls Ducted Systems
Available
Settings
Yes or No
Yes or No
-5°, -4°, -3°, -2°,
-1°, 0°,1°, 2°, 3°,
4°, 5°
-5%, -4%, -3%,
-2%, -1%, 0%, 1%,
2%, 3%, 4%, 5%
5 MIN, 10 MIN,
15 MIN, 20 MIN,
25 MIN, 30 MIN
None, Indoor, Out-
door, Average
OFF, 55°F, 60°F,
65°F, 70°F, 75°F,
80°F
10 MIN, 15 MIN,
20 MIN, 25 MIN
Explanation
Enables or disables smart recovery.
Smart recovery is used in Programma-
ble mode. The controller initiates equip-
ment operation, if required before the
start time of the program schedule day
part. This is done to reach the desired
temperature setpoint of the program
schedule event at the time the event
occurs, rather than after.
Enables or disables Fan On with W.
When enabled, this supplies a fan out-
put demand as soon as a W1 or W2
output demand is active
Allows you to adjust the displayed tem-
perature to offset it from the measured
temperature in the thermostat
Allows you to adjust the displayed
humidity to offset it from the measured
humidity in the thermostat
Sets the minimum time that must elapse
between switches from heat-to-cool to
cool-to-heat demands when operating
in Auto mode
If you opt to use the remote sensor, you
can set it to sense the indoor room tem-
perature or the outdoor temperature. If
you select the Average option, the
onboard temperature sensor and the
connected sensor are averaged to
determine the room temperature on the
thermostat.
When enabled, this setting prevents
cooling operation when the outdoor
temperature drops below the selected
temperature.
Sets the minimum time limit between
the switch from one fuel type to another
39