LDVT Series Direct Vent Gas Fireplace

Hearth

A hearth is not mandatory but is recommended for
aesthetic purposes. We recommend a noncombustible
hearth which projects out 12" (305mm) or more from the
front of the fireplace.
Cold climate installation recommendation:
When installing this unit against a non-
insulated exterior wall or chase, it is
mandatory that the outer walls be insulated
to conform to applicable insulation codes.
Framing and Finishing
Check fireplace to make sure it is levelled
and properly positioned.
To mount the appliance:
1. Choose the location.
2. This unit comes with four (4) flanges pre-mounted
on both sides of the fireplace to allow two different
drywall thicknesses to be used. Flange "A" is for
1/2" drywall while flange "B" is for 5/8" drywall.
3. Bend the desired flanges out 90° on both sides of
the fireplace. Slide the fireplace into the framed
opening until the flanges contact the front surfaces
of the framing. Level the unit and secure it firmly in
place.
Flange Location for Desired Drywall Depth
Flange
Drywall
Position
Depth
A
1/2" / 13 mm
B
5/8" / 16 mm
A
B
Fig . 4 Nailing flanges.

Final Finishing

Noncombustible materials such as brick or tile may be
extended over the edges of the face of the appliance.
DO NOT cover any vent or grille panels.
If a Trim Kit is going to be installed on the fireplace, the
brick or tile will have to be installed flush with the edges
of the appliance.
6
FP1546
FP1546
LDVT nailing flanges
1/05
Gas Specifications
Gas
Model
Fuel
Control
33LDVTRN
Nat
Millivolt 16,000
33LDVTRP
Prop
Millivolt 16,000
33LDVTEN
Nat
24V
Hi/Lo
33LDVTEP
Prop*
24V
Hi/Lo
36LDVTRN
Nat
Millivolt 19,500
36LDVTRP
Prop
Millivolt 19,500
36LDVTEN
Nat
24V
Hi/Lo
36LDVTEP
Prop*
24V
Hi/Lo
39LDVTRN
Nat
Millivolt 23,000
39LDVTRP
Prop* Millivolt 22,500
39LDVTEN
Nat
24V
Hi/Lo
39LDVTEP
Prop*
24V
43LDVTRN
Nat
Millivolt 26,000
43LDVTRP
Prop* Millivolt 24,000
43LDVTEN
Nat
24V
Hi/Lo
43LDVTEP
Prop*
24V
Hi/Lo
*Using conversion kit

Gas Inlet and Manifold Pressures

Inlet Minimum
Inlet Maximum
Manifold Pressure
Max.
Min.
Air
Input
Input
Shutter
BTU/h
BTU/h
Adj.
11,200
3/16"
Open
12,000 Fully Open
16,000
11,200
3/16"
Open
16,000
12,000 Fully Open
13,650
Top &
Bottom
Hole Half
Closed
14,625 Fully Open
19,500
13,650
Top &
Bottom
Hole Half
Closed
19,500
14,625 Fully Open
16,100
Top &
Bottom
Hole Half
Closed
16,875 Fully Open
23,000
16,100
Top &
Bottom
Hole Half
Closed
22,500
16,875 Fully Open
18,200
Top &
Bottom
Hole Half
Closed
18,000 Fully Open
26,000
18,200
Top &
Bottom
Hole Half
Closed
24,000
18,000 Fully Open
Natural
LP (Propane)
5.5" w.c.
11.0" w.c.
14.0" w.c.
14.0" w.c.
3.5" w.c.
10.0" w.c.
10007852