Vermont Castings Dutchwest 2465 Homeowner's Installation And Operating Manual page 16

Direct vent / natural vent gas heater
Table of Contents

Advertisement

Dutchwest Direct Vent / Natural Vent Gas Heater
For DuraVent pipe only: Install vent pipe by align-
ing the locking system together, sliding the pipes
together and twisting clockwise.
• Install 90° elbow. Twist lock as before.
• Slide the wall plate over horizontal run before at-
taching the horizontal run to the elbow. Fasten wall
plate to wall.
4. For CFM Vent Pipe only: If necessary, measure
to determine the vertical length (X) of pipe required
from the adapter pipe to the wall cutout centerline,
including a 2" (51mm) overlap at the joint. (Fig.
24) use a hacksaw or tin snips to trim the pipe as
needed.
Fig. 24 Determine the vertical pipe length.
5. Install first the inner then the outer straight pipe
ST764
section(s), trimmed end down, to the point of the el-
DW
bow. Drill 3 holes through each joint and fasten with
measure vertical vent
sheet metal screws.
5/15/03 djt
6. Seal and install the elbow using 3 sheet metal
screws at each joint.
7. Measure, and cut if needed, the appropriate length
of pipe section needed to make the connection
through the wall. Include a 2" overlap; i.e. from the
elbow to the outside wall face, about 2" or the dis-
tance required if installing a second 90° elbow. (Fig.
25)
8. Slip the wall plate and trim collar over the interior
end of the horizontal pipe and install into the wall
sleeve. Seal the joint inside the wall plate if needed
to keep cold air from being drawn into the home.
9. Seal the ends and connect the horizontal pipe to the
elbow. Fasten the wall plate to the pipe with three
sheet metal screws. Slide the trim collar up against
the wall plate to cover the screws. (Fig. 26)
16
X
ST764
X
Fig. 25 Measure the horizontal length.
Wall
Sleeve
ST216
Fig. 26 Install the horizontal pipe and wall plate parts.
10. For both CFM and DuraVent Systems: Install the
vent terminal. (Fig. 27) Apply high temperature seal-
ant one inch from the ends of the inner and outer
ST216
collars. Guide the inner and outer vent termination
install pipe thru wall
collars into the adjacent pipes. Double check that
the vent pipes overlap the collars by 2". Fasten the
12/6/99 djt
termination to the wall with the screws provided, and
caulk the joint with weatherproof sealant.
11. For CFM only: Install Charcoal Gray Pipe Rings
(#7FSDRG) or Polished Brass Pipe Rings (#7FS-
DRP) at pipe joints, if desired.
Seal Both
Terminal Ends
Caulk Plate Joint with
Weatherproof Sealant
Fig. 27 Install the vent terminal.
ST217
install wall terminal
12/6/99 djt
Trim Collar
ST215
measure thru wall
12/6/99 djt
Wall Plate
ST217
30001935
ST215

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dutchwest 2466

Table of Contents