Encore Multi-Fuel, Model 2547CE
Nominal heat output
Minimum flue draught
Mean flue gas temp
Efficiency (space heating)
Fuel size/type
up to 510 mm (20") Smokeless coal
Flue mass gas flow
CO Emissions (@ 13% O
)
2
Area Heated .............................. 129 sq. m (1400 sq.ft.)
Loading ....................................................... Front or top
Chimney connector:
for 8" flue collar ....................... 203 mm (8") diameter
for 6" flue collar ....................... 152 mm (6") diameter
Chimney flue size:
for 8" flue collar .......................203 mm (8") minimum
for 6" flue collar .......................152 mm (6") minimum
Flue exit position ....................... Reversible, top or rear
Primary air ... Manually set, thermostatically maintained
Ash handling system ..................... Removable ash pan
Glass panel ......................... High-temperature ceramic
Weight ................................................ 159 kg (350 lbs.)
657 mm
(25���")
Fig. 1 Encore MF dimensions.
2000971
Specifications
Wood
Smokeless Fuel
12.3 kW
7.7 kW
1
(42,000 BTU/hr) (26,270 BTU/hr)
12 Pa
12Pa
(0.048" WG)
(0.048"WG)
291°C (556°F)
267°C (513°F)
71.6%
66.7%
12.0 g/s
10.4 g/s
7900 ppm
3200 ppm
457 mm (18")
543 mm
(21���")
686 mm (27")
686 mm (27")
470 mm
(18���")
187 mm
(7���")
686 mm (27")
Width (leg-to-leg) ..................................... 685 mm (27")
2
Depth (leg-to-leg) .................................... 380 mm (15")
1
Height to top of flue collar, 152 or 203 mm (6" or 8")
Top exit .............................................. 640 mm (25¹⁄₄")
Rear exit ............................................ 675 mm (26¹⁄₂")
1. This value can vary depending on how the stove
is operated, the type and moisture content of the fuel
used, as well as the design, construction and climatic
location of your home. Figures shown are based on
nominal fuel consumption obtained under laboratory
conditions and on average efficiencies.
2. This stove is approved for use with processed coal
fuels generally known as smokeless. Ask your dealer
which fuels are acceptable in your area.
83 mm
(3���")
610 mm
(24")
51 mm
(2")
641 mm
(25���")
Top exit
flue collar
height
����
Encore MF 2547
dimensions
9/02
Encore Multi-Fuel Heater
Drawings Not to Scale
572 mm (22���")
127 mm
(5")
394 mm
(15���")
73 mm (2���")
600 mm
(23���")
133 mm
(5���")
381 mm
(15")
0971