To Turn Off Gas To Appliance; Manual Lighting Procedure - Vanguard VSGF28NTC Owner's Operation And Installation Manual

Unvented (vent-free) natural gas fireplace
Table of Contents

Advertisement

UNVENTED NATURAL GAS FIREPLACE
OPERATING
FIREPLACE
Continued
7.
Keep control knob pressed in for 30
seconds after lighting pilot. After 30
seconds, release control knob.
Note: If pilot goes out, repeat steps
3 through 7.
• If control knob does not pop out
when released, contact a qualified
service person or gas supplier for
repairs.
8. Slightly depress and turn control
knob counterclockwise
the HIGH position. Both burners
should light. Set control knob to ei-
ther HIGH or LOW.
Control Knob
Ignitor Button
Figure 29 - Control Knob and Ignitor
Button Location
Ignitor Electrode
Thermocouple
Figure 30 - Pilot
For more information, visit www.desatech.com
®
VARIABLE CONTROL
The variable control valve can be set to any
heat setting and flame height desired, by
simply turning the control knob until that
setting is attained. Even the lowest setting
provides realistic flames and glowing em-
bers from two burners. Selecting higher
settings produces greater heat output. This
results in increased heating comfort.
heater between locked positions.
to
C-clockwise
CAUTION: Do not try to adjust
heating levels by using the equip-
ment shutoff valve.
Shutting Off Fireplace
IGNITOR
1. Turn control knob clockwise
to the HIGH position.
2. Slightly depress control knob and
turn clockwise
position.
3. Slightly depress control knob and
Pilot Burner
turn clockwise
position.
Shutting Off Burners Only (pilot
stays lit)
1. Turn control knob clockwise
to the HIGH position.
2. Press in and turn clockwise
to the PILOT position.
OPERATION
WARNING: Do not operate
TO TURN OFF GAS
TO APPLIANCE
to the PILOT
Clockwise
to the OFF
Clockwise
16
MANUAL LIGHTING
PROCEDURE
1.
Follow steps 1 through 5 under Light-
ing Instructions, page 15.
2.
Depress control knob and light pilot
with match.
3.
Keep control knob pressed in for 30
seconds after lighting pilot. After 30
seconds, release control knob. Now
follow step 8, column 1.
Clockwise
Clockwise
Clockwise
Continued
107157

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vsgf28nva

Table of Contents