WARNING: If the information in this manual is not fol-
lowed exactly, a fire or explosion may result causing
property damage, personal injury or loss of life.
— Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other
appliance.
— WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any
phone in your building.
• Immediately call your gas supplier from a neighbor's
phone. Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire
department.
— Installation and service must be performed by a quali-
fied installer, service agency or the gas supplier.
For more information, visit www.desatech.com
VI33NRB AND VI33PRB
Save this manual for future reference.
®

Advertisement

Table of Contents
loading

Summary of Contents for Vanguard VI33NRB

  • Page 1 UNVENTED (VENT-FREE) GAS FIREPLACE INSERT OWNER’S OPERATION AND INSTALLATION MANUAL Shown with GS38 Surround Kit and G8010 Brick Liner Accessories VI33NRB AND VI33PRB REMOTE READY GAS FIREPLACE INSERT WARNING: If the information in this manual is not fol- lowed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
  • Page 2: Table Of Contents

    WARNING: Improper installation, adjustment, altera- tion, service or maintenance can cause injury or prop- erty damage. Refer to this manual for correct installation and operational procedures. For assistance or addi- tional information consult a qualified installer, service agency or the gas supplier. WARNING: This is an unvented gas-fired heater.
  • Page 3: Safety Information

    SAFETY INFORMATION WARNING: Do not use a blow- WARNING: This product con- er insert, heat exchanger insert tains and/or generates chemicals or other accessory not approved known to the state of California for use with this fireplace. to cause cancer or birth defects or other reproductive harm.
  • Page 4 SAFETY INFORMATION 10. This fireplace insert needs fresh air ventila- tion to run properly. This fireplace insert has Continued an Oxygen Depletion Sensing (ODS) safety shutoff system. The ODS shuts down the You must operate this fireplace fireplace insert if not enough fresh air is avail- insert with the fireplace insert able.
  • Page 5: Local Codes

    SAFETY INFORMATION PRODUCT Continued IDENTIFICATION 23. Refractory, glass doors, screen rails, screen Three Piece mesh and solid-fuel log grates (if applicable) Log Set can be removed from the fireplace before installing the unvented fireplace insert. Optional 24. Smoke shelves, shields and baffles may be Remote removed if attached by mechanical fasteners.
  • Page 6: Product Features

    PRODUCT FEATURES Exhaust fans, fireplaces, clothes dryers and fuel burning appliances draw air from the house to OPERATION operate. You must provide adequate fresh air for This vent-free fireplace insert is clean burning. It these appliances. This will insure proper venting requires no outside venting.
  • Page 7 AIR FOR COMBUSTION * Do not include direct-vent gas appliances. Di- rect-vent draws combustion air from the outdoors AND VENTILATION and vents to the outdoors. Continued Example: 40,000 Gas water heater __________ Btu/Hr Confined and Unconfined Space 33,000 Vent-free fireplace + _________ Btu/Hr The National Fuel Gas Code ANSI Z223.1/NFPA 54 73,000...
  • Page 8: Installation

    AIR FOR COMBUSTION Ventilated AND VENTILATION Outlet Attic Continued Outlet VENTILATION AIR To Attic Ventilation Air From Inside Building This fresh air would come from an adjoining un- Crawl Space confined space. When ventilating to an adjoining Inlet unconfined space, you must provide two perma- Ventilated nent openings: one within 12"...
  • Page 9 CAUTION: A GS38 or GS43 qualified chimney cleaner. surround kit accessory must be Note: Your Vanguard fireplace insert is designed installed on this fireplace insert to be used in zero clearance installations. Wall or before installing into your ma- framing material can be placed directly against any sonry fireplace or wall opening.
  • Page 10 INSTALLATION Continued 4. Using Phillips screwdriver, remove four screws attaching top louver (see Figure 7). 5. Place top surround panel at top of fireplace insert. Bottom edge of panel will slide under top edge of insert. Align top panel screw holes with those in insert.
  • Page 11 INSTALLATION Continued Example INSTALLING HOOD Install hood to top of firebox as shown in Figure 10. Use 5 Phillips screws, provided, to attach hood to fireplace insert and 2 Phillips screws, provided, to attach hood and surround sides to fireplace insert. Mantel Clearances for Insert Installation If there is a mantel above masonry fireplace, you must meet minimum clearance between mantel...
  • Page 12 INSTALLATION Continued Wall board or facing material (above fireplace) may be of Mantel Shelf combustible material, 10" including decorative mantel ornaments or 8" other similar projec- 6" tions off of the facing material. 1 /2 " Fireplace Noncombustible Material May Project Off this Surface above Fireplace Insert...
  • Page 13 INSTALLATION Continued CAUTION: Use only new, black iron or steel pipe. Inter- nally-tinned copper tubing may be used in certain areas. Check your local codes. Use pipe of 1/2" diameter or greater to allow proper gas volume to fireplace insert. If pipe is too small, undue loss of volume will occur.
  • Page 14 3. Route gas supply line through access opening of fireplace insert (see Figure 15). NOTICE: Most building codes do not permit concealed gas connections. A flexible gas line is provided to allow accessibility from the fireplace (see Figure 16). The flexible gas supply line con- nection to the equipment shutoff valve should be accessible.
  • Page 15 INSTALLATION Continued Test Pressures Equal To or Less Than 1/2 PSIG (3.5 kPa) 1. Close equipment shutoff valve (see Figure 17). 2. Pressurize supply piping system by either open- ing propane/LP supply tank for propane/LP gas or opening main gas valve located on or near gas meter or using compressed air.
  • Page 16 INSTALLATION 6. While firmly holding edges of trim together, tighten both set screws on the adjusting plate Continued with slotted screwdriver. 3. Install gas piping to fireplace location. This 7. Repeat steps 3 through 6 for other side. installation includes an approved flexible gas 8.
  • Page 17 INSTALLATION Continued Burner Ports Figure 24 - Installing Log Set (Top View) Screws for Mounting Screen Notches Figure 25 - Installing Fireplace Insert Screen 113195-01B www.desatech.com...
  • Page 18 INSTALLATION Continued OPTIONAL WIRELESS HAND-HELD REMOTE CONTROL ACCESSORIES (GHRCB and GHRCTB) Installing Remote Receiver Unit 1. Disconnect switch wires from the control valve. 2. Remove screws attaching switch plate. 3. Remove switch plate (see Figure 26). Discard after removing. 4. Install remote receiver unit onto gas log heater base using mounting clips.
  • Page 19: Operating Fireplace Insert

    OPERATING FIREPLACE NOTICE: During initial operation INSERT of new fireplace insert, burning logs will give off a paper-burning FOR YOUR SAFETY smell. Open damper or window READ BEFORE LIGHTING to vent smell. This will only last a few hours. WARNING: If you do not fol- low these instructions exactly, 1.
  • Page 20 OPERATING FIREPLACE INSERT Continued 7. With control knob pressed in, press and release ignitor button. This will light pilot. The pilot is attached to the front burner. If needed, keep pressing ignitor button until pilot lights. Note: If pilot does not stay lit, contact a qualified service person or gas supplier for repairs.
  • Page 21 OPERATING FIREPLACE INSERT Continued Flame Adjustment Knob Control Knob Remote Selector Switch in in On Position Remote Position (Optional Hand-Held Remote Control) Figure 34 - Setting the Remote Selector Switch, Control Knob and Flame Adjustment Knob for Remote Operation ON/OFF SERIES (MODEL GHRCB) Hold the control button on the hand-held remote until burner turns on.
  • Page 22: Inspecting Burners

    OPERATING FIREPLACE INSPECTING BURNERS INSERT Check pilot flame pattern and burner flame pat- terns often. Continued PILOT FLAME PATTERN Auto Shutoff Feature 1. If the average room temperature exceeds Figure 37 shows a correct pilot flame pattern. 82 degrees Fahrenheit (28 degrees Centi- Figure 38 shows an incorrect pilot flame pattern.
  • Page 23: Cleaning And Maintenance

    INSPECTING BURNERS CLEANING AND Continued MAINTENANCE BURNER FLAME PATTERN WARNING: Turn off heater Figure 39 shows a correct burner flame pattern. and let cool before cleaning. Figure 40 shows an incorrect burner flame pattern. If burner flame pattern is incorrect, •...
  • Page 24: Wiring Diagrams

    CLEANING AND Clean the pilot assembly also. A yellow tip on the pilot flame indicates dust and dirt in the pilot as- MAINTENANCE sembly. There is a small pilot air inlet hole about Continued two inches from where the pilot flame comes out of the pilot assembly (see Figure 42).
  • Page 25: Troubleshooting

    TROUBLESHOOTING WARNING: Turn off heater and let cool before servicing. Only a qualified service person should service and repair heater. CAUTION: Never use a wire, needle or similar object to clean ODS/pilot. This can damage ODS/pilot unit. Note: All troubleshooting items are listed in order of operation. OBSERVED PROBLEM REMEDY POSSIBLE CAUSE...
  • Page 26 TROUBLESHOOTING Continued OBSERVED PROBLEM REMEDY POSSIBLE CAUSE ODS/pilot lights but flame 1. Press in control knob fully 1. Control knob not fully pressed in goes out when control knob is 2. After ODS/pilot lights, keep con- 2. Control knob not pressed in released trol knob pressed in 30 seconds long enough...
  • Page 27 TROUBLESHOOTING Continued OBSERVED PROBLEM REMEDY POSSIBLE CAUSE Slight smoke or odor during 1. Check burner for dirt and 1. Not enough air initial operation debris. If found, clean burner (see Cleaning and Mainte- nance, page 23) 2. Replace gas control 2.
  • Page 28 TROUBLESHOOTING Continued WARNING: If you smell gas • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone. Fol- low the gas supplier’s instructions.
  • Page 29: Specifications

    SPECIFICATIONS TECHNICAL SERVICE You may have further questions about installation, VI33NRB VI33PRB operation or troubleshooting. If so, contact DESA Btu (Variable) 22,000/30,000 22,000/30,000 Heating Productsʼ Technical Service Department Type Gas Natural Gas Propane/LP at 1-866-672-6040. When calling please have your...
  • Page 30: Illustrated Parts Breakdown And Parts List

    ILLUSTRATED PARTS BREAKDOWN MODELS VI33NRB AND VI33PRB Note: Items 27 and 28 are for natural gas only www.desatech.com 113195-01B...
  • Page 31 PARTS LIST This list contains replaceable parts used in your fireplace insert. When ordering parts, follow the instruc- tions listed under Replacement Parts on page 29 of this manual. PART NUMBER VI33NRB VI33PRB DESCRIPTION QTY. 113548-02 113548-02 Back Log 113549-02...
  • Page 32 ILLUSTRATED PARTS BREAKDOWN FIREPLACE INSERT MODELS VI33NRB AND VI33PRB www.desatech.com 113195-01B...
  • Page 33 PARTS LIST FIREPLACE INSERT MODELS VI33NRB AND VI33PRB This list contains replaceable parts used in your fireplace insert. When ordering parts, follow the instruc- tions listed under Replacement Parts on page 29 of this manual. PART NUMBER DESCRIPTION QTY. 105517-01...
  • Page 34: Accessories

    ACCESSORIES Purchase these fireplace insert accessories from your local dealer. If they can not supply these accessories, call DESA Heating Productsʼ Sales Department at 1-866-672-6040 for information. You can also write to the address listed on the back RECEIVER AND HAND-HELD page of this manual.
  • Page 35 NOTES _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ 113195-01B www.desatech.com...
  • Page 36: Warranty Information

    WARRANTY INFORMATION KEEP THIS WARRANTY Model Serial No. Date Purchased Always specify model and serial numbers when communicating with the factory. We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written warranty.

This manual is also suitable for:

Vi33prb

Table of Contents