Carrier WeatherExpert 48LC Series Service And Maintenance Instructions page 53

Single package rooftop gas heating/electric cooling unit
Table of Contents

Advertisement

PARAMETER
PARAMETER
GROUP
NUMBER
9902
9905
9906
START-UP
DATA
9907
9908
9909
1001
START/STOP/
DIR
1003
1103
REFERENCE
1104
SELECT
1105
1201
1202
CONSTANT
SPEEDS
1203
1204
1301
ANALOG
INPUTS
1302
1401
RELAY
1402
OUTPUTS
1403
1604
SYSTEM
CONTROL
1608
OVERRIDE
1701
2003
LIMITS
2007
2008
2101
START/STOP
2102
2109
2201
ACCEL/DECEL
2202
2203
2606
MOTOR
2607
3005
3006
FAULT
3007
FUNCTIONS
3008
3009
3104
AUTOMATIC
3105
RESET
3106
5301
5302
EFB
5303
PROTOCOL
5304
5305
OPTIONS
9802
Table 28 — 48LC 05-06 VFD Parameters
UNIT SIZE
2.4 HP 208-
Motor Description
230v
Drive/Motor Voltage
208-230v
Motor Part Number
HD56FE653
VFD Part Number
HK30WA001
ACH550-
ABB Part Number
CARUH
-012A-2
(1) HVAC
Application Macro
DEFAULT
Motor Nominal Voltage
Motor Nominal Current
Motor Nominal
Frequency
Motor Nominal Speed
1725
Motor Nominal Power
EXT1 Commands
(1) DI1
Direction
(1) Forward
REF1 Select
(1) AI1
REF1 Minimum
0 Hz
REF1 Maximum
60 Hz
Constant Speed Select
(8) DI2,3
Constant Speed 1
42.6
Constant Speed 2
60 Hz
Constant Speed 3
60 Hz
Minimum AI-1
20.00%
Maximum AI-1
100.00%
Relay Output 1
(1) Ready
Relay Output 2
(2) Run
(16) FLT/
Relay Output 3
ALARM
Fault Reset Sel
(0) Keypad
Start Enable 1
(4) DI4
Override Sel
(0) NOT SEL
Maximum Current
Minimum Frequency
0.0 Hz
Maximum Frequency
60 Hz
Start Function
(1) AUTO
Stop Function
(1) Coast
EM STOP Sel
(0) NOT SEL
Acc/Dec 1/2 Sel
(0) NOT SEL
Accelerate Time
30.0 s
Decelerate Time
10.0 s
Switching Frequency
4 kHz
Switching Frequency
(1) ON
Control
Motor Therm Prot
(1) Fault
Motor Thermal Time
1050 s
Motor Load Curve
100%
Zero Speed Load
%00705
Break Point Frequency
35 Hz
AR Overcurrent
(0) DISABLE
AR Overvoltage
(1) ENABLE
AR Undervoltage
(1) ENABLE
EFB PROTOCOL ID
0601 (hex)
EFB STATION ID
EFB BAUD RATE
38400
EFB PARITY
8 NONE 1
EFB CTRL PROFILE
DCU PROFILE
COMM PROT SEL
6 (LEN)
48LC 06
2.4 HP 460v
460v
HD56FE653
HK30WA008
ACH550-
CARUH
-06A9-4
(1) HVAC
DEFAULT
230
460
7.9
4.0
60
60
1725
2.4
2.4
(1) DI1
(1) Forward
(1) AI1
0 Hz
60 Hz
(8) DI2,3
42.6
60 Hz
60 Hz
20.00%
100.00%
(1) Ready
(2) Run
(16) FLT/
ALARM
(0) Keypad
(4) DI4
(0) NOT SEL
9.1
4.6
0.0 Hz
60 Hz
(1) AUTO
(1) Coast
(0) NOT SEL
(0) NOT SEL
30.0 s
10.0 s
4 kHz
(1) ON
(1) Fault
1050 s
100%
%00705
35 Hz
(0) DISABLE
(1) ENABLE
(1) ENABLE
0601 (hex)
41
41
38400
8 NONE 1
DCU PROFILE
DCU PROFILE
6 (LEN)
53
48LC 05/06
2.9 HP 208-
2.9 HP 460v
230v
208-230v
460v
HD58FE654
HD58FE654
HK30WA001
HK30WA008
ACH550-
ACH550-
CARUH
CARUH
-012A-2
-06A9-4
(1) HVAC
(1) HVAC
DEFAULT
DEFAULT
230
460
9.2
4.6
60
60
1725
1725
2.4
2.4
(1) DI1
(1) DI1
(1) Forward
(1) Forward
(1) AI1
(1) AI1
0 Hz
0 Hz
60 Hz
60 Hz
(8) DI2,3
(8) DI2,3
41.2
41.2
60 Hz
60 Hz
60 Hz
60 Hz
20.00%
20.00%
100.00%
100.00%
(1) Ready
(1) Ready
(2) Run
(2) Run
(16) FLT/
(16) FLT/
ALARM
ALARM
(0) Keypad
(0) Keypad
(4) DI4
(4) DI4
(0) NOT SEL
(0) NOT SEL
10.6
5.3
0.0 Hz
0.0 Hz
60 Hz
60 Hz
(1) AUTO
(1) AUTO
(1) Coast
(1) Coast
(0) NOT SEL
(0) NOT SEL
(0) NOT SEL
(0) NOT SEL
30.0 s
30.0 s
10.0 s
10.0 s
4 kHz
4 kHz
(1) ON
(1) ON
(1) Fault
(1) Fault
1050 s
1050 s
100%
100%
%00705
%00705
35 Hz
35 Hz
(0) DISABLE
(0) DISABLE
(1) ENABLE
(1) ENABLE
(1) ENABLE
(1) ENABLE
0601 (hex)
0601 (hex)
41
41
38400
38400
8 NONE 1
8 NONE 1
DCU PROFILE
6 (LEN)
6 (LEN)
3.7 HP 575v
575v
HD58FE577
HK30WA021
ACH550-
CARUH
-06A1-6
(1) HVAC
DEFAULT
575
4.2
60
1725
2.4
(1) DI1
(1) Forward
(1) AI1
0 Hz
60 Hz
(8) DI2,3
41.2
60 Hz
60 Hz
20.00%
100.00%
(1) Ready
(2) Run
(16) FLT/
ALARM
(0) Keypad
(4) DI4
(0) NOT SEL
4.8
0.0 Hz
60 Hz
(1) AUTO
(1) Coast
(0) NOT SEL
(0) NOT SEL
30.0 s
10.0 s
4 kHz
(1) ON
(1) Fault
1050 s
100%
%00705
35 Hz
(0) DISABLE
(1) ENABLE
(1) ENABLE
0601 (hex)
41
38400
8 NONE 1
DCU PROFILE
6 (LEN)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents