SPECIFICATIONS

Btu (Variable)
Type Gas
Ignition
Pressure Regulator Setting
Inlet Gas Pressure (in. of water)
Maximum
Minimum
Dimensions, Inches (H x W x D)
Heater (Includes knobs & grill)
Carton
Weight (pounds)
Heater
Shipping
ACCESSORIES
Purchase these heater accessories from your
local dealer. If they can not supply these
accessories, call DESA International's Parts
Department at 1-800-972-7879 for referral
information. You can also write to the ad-
dress listed on the back page of this manual.
FLOOR MOUNTING STAND
Model VP2000BTD - GA4000B
Model VP2800BTD - GA4010B
For locating heater on the floor, away from
a wall. Complete installation
instructions included.
EQUIPMENT SHUTOFF
VALVE - GA5010
For all models. Equipment shutoff valve with
1/8" NPT tap.
104401
VP2000BTD
VP2800BTD
10,000/20,000
15,000/30,000
Propane/LP Only
Propane/LP Only
Piezo
Piezo
8" W.C.
8" W.C.
14"
14"
11"
11"
23.5 x 18.5 x 8.0
23.5 x 25.9 x 8.0
26 x 20.5 x 9.63
26 x 27.75 x 9.63
22
30
27
35
FAN KITS - GA3100(A,B) AND
GA3200T(A,B)
For all models. Provides better heat distribu-
tion. Makes heater more efficient. Complete
installation and operating instructions included.
Manually-controlled - GA3100(A,B). In-
cludes ON/OFF switch.
Thermostatically-controlled - GA3200T(A,B).
Includes three settings: ON/OFF/AUTO.
TECHNICAL
SERVICE
You may have further questions about in-
stallation, operation, or troubleshooting.
If so, contact DESA International's Techni-
cal Service Department at 1-800-323-5190.
You can also visit DESA International's
technical
service
www.desatech.com.
SERVICE
PUBLICATIONS
You can purchase service manual from the
address listed on the back page of this
manual. Send a check for $5.00 payable to
DESA International.
17
OWNER'S MANUAL
REPLACEMENT
PARTS
Note: Use only original replacement parts.
This will protect your warranty coverage for
parts replaced under warranty.
PARTS UNDER WARRANTY
Contact authorized dealers of this product.
If they can't supply original replacement
part(s), call DESA International's Techni-
cal Service Department at 1-800-323-5190.
When calling DESA International, have ready
• your name
• your address
• model and serial numbers of your heater
• how heater was malfunctioning
• type of gas used (propane/LP or natural gas)
• purchase date
Usually, we will ask you to return the defec-
tive part to the factory.
PARTS NOT UNDER
WARRANTY
Contact authorized dealers of this product.
If they can't supply original replacement
part(s), call DESA International's Parts
Department at 1-800-972-7879 for referral
information.
When calling DESA International, have ready
• model number of your heater
• the replacement part number

SERVICE HINTS

When Gas Pressure Is Too Low
• pilot will not stay lit
• burner will have delayed ignition
• heater will not produce specified heat
• propane/LP gas supply may be low
web
site
at
When Gas Quality Is Bad
• pilot will not stay lit
• burner will produce flames and soot
• heater will backfire when lit
You may feel your gas pressure is too low or
gas quality is bad. If so, contact your local
propane/LP gas supplier.