Troubleshooting Chart - Dyna-Glo Delux RMC-FA150NGDGD Operating Instructions & Parts Manual

Natural gas construction heater
Hide thumbs Also See for Delux RMC-FA150NGDGD:
Table of Contents

Advertisement

Dyna-Glo Delux Operating Instructions and Parts Manual
Dyna-Glo
Construction Heater

Troubleshooting Chart

Symptom
Fan does not turn when
electrical connection is
made
Heater will not fire
Heater quits while
running
Always be sure to follow proper maintenance procedures, by cleaning the heater once per month during regular usage, and
check spark gap at least once per season.
For Technical Support or Troubleshooting, Call: 1-877-447-4768, 8:30 am - 4:30 pm CST
Delux Natural Gas
®
Possible Cause(s)
1. No electric power to heater
2. Fan blade contacts inside of heater
housing
3. Fan blade(s) bent
4. Fan motor defective
1. No spark at igniter
2. Improper spark gap
3. Bad electrode
1. Internal temperature too high causing
limit switch to shut down operation
2. Damaged control valve
3. Dust or debris build-up inside of heater
NEVER LEAVE THE HEATER
UNATTENDED WHILE BURNING!
Corrective Action
1. Check current to electric outlet. If voltage is
correct, check power cord and extension cord for
cuts and breaks
2. Be sure that housing is not damaged. Make sure
there are no obstructions to the fan
3. Straighten blade(s) to match others
4. Replace motor
1. Check igniter wire. Reattach or tighten if loose.
Check spark module. Replace if necessary. Check
all electrical components
2. Set gap to 0.12" (3 mm)
3. Replace spark plug
1. If the heaters output is restricted, internal temp-
era ture becomes too high. Move heater away
from any obstructions
2. Replace control valve
3. Clean inside of heater
8
RMC-FA150NGDGD
www.ghpgroupinc.com

Advertisement

Table of Contents
loading

Table of Contents