[Adjustment of ballast unit output power (lamp power)] 
 
1. List of parts requiring adjustment 
 
When replacing the following parts, adjust the ballast unit output power (lamp power). 
 
Part name
 
1
Cement resistor
2
Control PWB
Ballast microprocessor
3
4
5V regulator 
PWM controller 
5
 
 
2. Adjustment jigs 
 
The following jigs are required for adjusting the ballast unit output power (lamp power). 
 
Part name
 
1
Adjustment jig (resistance load 25Ω) 
Connecting cord (conversion cable) 
2
3. Ballast unit output power (lamp power) adjustment method 
 
Adjust the ballast unit output power (lamp power) in the following method. 
 
[Setting method] 
 
 
XG-MB50X 
X R-11XC 
X R-10S/X 
X R-20S/X 
  Projector
[Adjustment method] 
(1)Unplug the ballast unit lamp cable(QCNW-D573WJQZ)  of the XR10/20 projector from  
  
the lamp and connect the cable to the connecting cord (QCNW-E007WJZZ). 
(2) Connect the connecting cord (QCNW-E007WJZZ) to the adjustment jig  
  
(RUNTZA018WJZZ). 
(3) Connect TP1 of the adjustment jig (RUNTZA018WJZZ) to the negative terminal of the  
  
tester and TP2 to the positive terminal. 
(4) Turn on the XR10/20 projector. 
(5) Age the projector for 60 seconds or more. 
(6) Adjust the volume resistor (R7728) of the ballast control PWB (DUNTKD148WEF0) so  
  
that the voltage of the tester reaches 83± 0.5 V. 
 
        Adjustment value: 83± 0.5 V 
 
[Cautions] 
(1) Caution for electric shock: Do not touch the test points TP1 and TP2 of the adjustment  
  
jig when supplying power since a high voltage and large current is applied to them. 
(2) Caution for heat: Be careful that the resistance load of the adjustment jig produces a high  
  
temperature when supplying power. 
(3) Connection of the lamp cable: Check that the lamp cable and connecting cord (QCNW-E 
  
007WJZZ) are connected securely. 
  
Poor connection may cause smoking or ignition due to arc discharge. 
 
 
Ref No.
Part code
R905
RR-FZA002WJZZ
DUNTKD148WEF0
--
RH-iXB458WJZZ
IC7707
 
IC7704
VHITA78L05F-1Y
VHIM51995AF-1Y
IC7701
Part code
RUNTZA018WJZZ
QCNW-E007WJZZ
Ballast Unit
Lamp Cable
(QCNW-D573WJQZ)
C onnecting  C ord
(Q C N W -E007WJZZ)
29
Manufacturer 
 
Asahi Communication 
 
SMK
Tester 
(Voltage) 
 
− 
+ 
  
TP1
Adjustment  Jig
(RU N T ZA 018WJZZ)
TP2
XG-MB50X
XR-11XC
XR-10X/S
XR-20X/S

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xr-11xcXr-10xXr-20xXr-10sXr-20s

Table of Contents