PowerScan™ PM9501-AR Family
Industrial Cordless Handheld
Auto Range Area Imager
Bar Code Reader
Quick Reference Guide

Advertisement

Table of Contents
loading

Summary of Contents for Datalogic PowerScan PM9501-AR Series

  • Page 1 PowerScan™ PM9501-AR Family Industrial Cordless Handheld Auto Range Area Imager Bar Code Reader Quick Reference Guide...
  • Page 2 Datalogic has taken reasonable measures to provide informa- tion in this manual that is complete and accurate, however, Datalogic reserves the right to change any specification at any time without prior notice. Datalogic and the Datalogic logo are registered trademarks of Datalogic S.p.A. in many countries, including the U.S.
  • Page 3: Table Of Contents

    Resetting Product Defaults ..........6 Compatibility with the PowerScan™ 8000 family ....7 Set Date and Time ................7 Linking the Reader................8 Link Datalogic RF Devices to Base......8 Power Off ..................8 Operating Mode................9 Scan Mode ................9 Pick Mode..................
  • Page 4 NOTES PowerScan™ PM9501-AR...
  • Page 5: End User Software License Agreement

    Software, (ii) copy the func- tionality of the Datalogic Products; (iii) remove any proprietary notices, marks, labels, or logos from the Datalogic Products; (iv) rent or transfer all or some of the Software to any other party without Datalogic's prior written consent.
  • Page 6 Software is used with the Datalogic Product. Datalogic' s entire liability and End User' s sole and exclusive remedy for any breach of the foregoing limited warranty will be, at Datalogic' s option, the pro- vision of a downloadable patch or replacement software.
  • Page 7 Notices to Datalogic shall be sent to the attention of Datalogic IP Tech S.r.l., Legal & IP Department, Via San Vitalino 13, 40012 Calderara di Reno (Bologna), Italy, or such other address as may be specified by Datalogic in writing.
  • Page 8: Software Product Policy

    - END - Software Product Policy Datalogic reserves the right to ship its products with the latest version of software/firmware available. This pro- vides our customers with the very latest in Datalogic soft- ware technology.
  • Page 9: Description

    Powerscan™ PM9501-AR Description The PowerScan™ PM9501-AR is a feature-rich and rugged area imager scanner with auto range reading capability, due to the implementation of autofocus system. Model P/N Features PM9501-ARXX Auto Range optic PM9501-DARXX Auto Range optic, Display and 4 keys keypad PM9501-DKARXX Auto Range optic, Display and 16 keys keypad General Features...
  • Page 10: Using The Powerscan™ Pm9501-Ar

    Using the PowerScan™ PM9501-AR Using the PowerScan™ PM9501-AR The PowerScan™ PM9501-AR normally functions by cap- turing and decoding 1D and 2D codes. The intelligent aim- ing system indicates the field of view which should be positioned over the code. The reader is equipped with an aiming system which helps to aim the target.
  • Page 11: Installing The Battery Pack

    To install, charge and/or do any other action on the bat- tery, follow the instructions in this manual. To charge the Battery Pack, See “Charging the Batteries” on page 6. Datalogic recommends annual replacement of rechargeable battery packs to ensure maxi- mum performance. NOTE Do not discharge the battery using any device except for the scanner.
  • Page 12 Installing the Battery Pack Always charge the battery at 32° – 104°F (0° - 40°C) temperature range. Use only the authorized power supplies, battery pack, chargers, and docks supplied by your Data- logic reseller. The use of any other power supplies can damage the device and void your warranty.
  • Page 13: Charging The Batteries

    Charging the Batteries Charging the Batteries Once the BC 90x0 is powered, you can charge the reader's ™ batteries. Place the PowerScan M9501-AR into the BC 90x0 cradle. The Reader LED on the cradle/battery charger turns red. The battery is completely charged when the Reader LED on the cradle/battery charger turns green.
  • Page 14: Programming

    Programming Programming The reader is factory-configured with a set of standard default features. Customize your reader through use of the programming bar codes available in the PowerScan PM9501-AR. Check the corresponding features section for your interface, and also the Data Editing and Symbologies chapters of the PRG.
  • Page 15: Compatibility With The Powerscan™ 8000 Family

    Set Date and Time Compatibility with the PowerScan™ 8000 family The PM9501-AR can be programmed to operate in a mode compatible with the PowerScan 8000 family. For further details and for the relevant configuration strings and labels, refer to the PRG. Set Date and Time 1.
  • Page 16: Linking The Reader

    Linking the Reader Linking the Reader Link Datalogic RF Devices to Base For RF devices, before configuring the interface it is nec- essary to link the handheld with the base. To link the handheld and the base, press the trigger to wake up the handheld, and mount it on the base.
  • Page 17: Operating Mode

    Operating Mode Operating Mode Scan Mode The imager can be set to operate in one of several scan- ning modes. See the PRG for more information and set- tings for any of the options: Trigger Single (Default)When the trigger is pulled, scanning is activated until one of the following occurs: •...
  • Page 18 Operating Mode Operating Mode (continued) ENTER/EXIT PROGRAMMING MODE   Scan Mode = Trigger Scan Mode = Pulse Multiple Trigger Single Scan Mode = Flashing Scan Mode = Trigger Hold Multiple Scan Mode = Always On PowerScan™ PM9501-AR...
  • Page 19: Pick Mode

    Pick Mode Pick Mode Pick Mode is a Decoding and Transmission process where bar codes that are not within the configurable distance from the center of the aiming pattern are not acknowl- edged or transmitted to the host. It is active only in Trigger Single mode.
  • Page 20: Technical Specifications

    Technical Specifications Technical Specifications The following tables contain Physical and Performance Characteristics, User Environment and Regulatory infor- mation. Physical Characteristics Height: 212 mm Dimensions Length: 110 mm Width: 74 mm PM9501-ARXX: 460 g Weight PM9501-DARXX: 485 g PM9501-DKARXX: 485 g Electrical Characteristics Battery Type Li-Ion battery pack...
  • Page 21 Technical Specifications Depth of Field) Symbology 10 mils: 15 - 160 cm 40 mils: 50 - 1100 cm Code 39 55 mils: 70 - 1150 cm 100 mils: up to 2300 cm EAN 13 mag. 1: 20 - 290 cm 15 mils: 30 - 330 cm Code 128 40 mils: 60 - 850 cm...
  • Page 22 Technical Specifications User Environment Operating Tempera- -4° to 122° F (-20° to 50° C) ture Storage Temperature -40° to 158° F (-40° to 70° C) Humidity 0 to 95% non-condensing Scanner withstands up to 50 times 6.5' Drop Specifications (2 m) drops to concrete Ambient Light Immu- 100,000 Lux nity...
  • Page 23: Led And Beeper Indications

    LED and Beeper Indications LED and Beeper Indications The reader’s beeper sounds and its LED illuminates to indicate various functions or errors on the reader. An optional “Green Spot” also performs useful functions. The following tables list these indications. One exception to the behaviors listed in the tables is that the reader’s func- tions are programmable, and so may or may not be turned on.
  • Page 24 LED and Beeper Indications Table 2. Error Indicators INDICATION DESCRIPTION BEEPER The reader is Link Attempt trying to link to Slow Flashes the base Reader and Base Configura- are aligning the tion Align- Fast Flashes parameters' con- ment figuration The reader has 3 beeps of successfully Link...
  • Page 25 LED and Beeper Indications Programming Mode - The following indications ONLY occur when the reader is in Programming Mode. INDICATION DESCRIPTION BEEPER Label Pro- A valid program- LED blinks Reader sounds gramming ming label has continu- four low fre- Mode Entry been scanned.
  • Page 26: Error Codes

    Error Codes Error Codes Upon startup, if the reader sounds a long tone, this means the reader has not passed its automatic Selftest and has entered FRU (Field Replaceable Unit) isolation mode. If the reader is reset, the sequence will be repeated. Press and release the trigger to hear the FRU indication code.
  • Page 27: Cleaning

    Cleaning Cleaning Exterior surfaces and scan windows exposed to spills, smudges or debris require periodic cleaning to ensure best performance during scanning. Use a soft, dry cloth to clean the product. If the product is very soiled, clean it with a soft cloth moistened with a diluted non-aggressive cleaning solution or diluted ethyl alcohol.
  • Page 28: Datalogic Limited Factory Warranty

    Datalogic hardware products are warranted against defects in material and workmanship under normal and proper use. The liability of Datalogic under this warranty is limited to furnishing the labor and parts necessary to remedy any defect cov- ered by this warranty and restore the product to its normal operating condition.
  • Page 29 Datalogic. Datalogic shall assume risk of loss or damage for product in Datalogic’s possession. In the absence of specific written instruc- tions for the return of product to Customer, Datalogic will select the carrier, but Datalogic shall not thereby assume any liability in connec- tion with the return shipment.
  • Page 30: Ergonomic Recommendations

    Provide a suitable working environment • Improve work procedures. Support Through the Website Datalogic provides several services as well as technical support through its website. Log on to www.datalogic.com. For quick access, from the home page click on the search icon , and type in the name of the product you're look- ing for.
  • Page 31: Hex-Numeric Keypad

    Hex-Numeric Keypad Hex-Numeric Keypad Use the barcodes that follow to enter numbers or alpha characters as you would select characters from a keypad. Quick Reference Guide...
  • Page 32 Hex-Numeric Keypad Hex-Numeric Keypad (continued) PowerScan™ PM9501-AR...
  • Page 33 Hex-Numeric Keypad Hex-Numeric Keypad (continued) Quick Reference Guide...
  • Page 34 Hex-Numeric Keypad NOTES PowerScan™ PM9501-AR...
  • Page 36 ©2013-2019 Datalogic S.p.A. and/or its affiliates. All rights reserved. Datalogic and the Datalogic logo are registered trademarks of Datalogic S.p.A. in many countries, including the U.S. and the E.U. Datalogic USA Inc. 959 Terry Street | Eugene, OR 97402 | U.S.A. |...

Table of Contents