Connecting The Rs-485 Device - Samsung SRD-830 User Manual

8 channel/16 channel dvr
Hide thumbs Also See for SRD-830:
Table of Contents

Advertisement

connecting with other device
 ALARM IN 1 ~ 8 (SRD-830/830D/850/850D/870/870D) : Alarm Input Port
 ALARM IN 1 ~ 16 (SRD-1610/1610D/1630/1630D/1650/1650D/1670/1670D) : Alarm Input Port
 ALARM RESET : On receiving an Alarm Reset signal, the system cancels the current Alarm Input and resumes
sensing.
 ALARM OUT 1 ~ 4 : Alarm Output Port
 ALARM OUT

CONNECTING THE RS-485 DEVICE

Connect the RS-485 device through the back port.
M
 You can connect and control the PTZ camera which supports the RS-485 communication.
 Transfer Type : You may select either Half Duplex or
Full Duplex as the data transfer type.
Baud Rate : Supported Baud rates are 600/1200/
2400/4800/9600/19200/38400.
M
Check if the RS-485 device is compatible with the
product first.
Pay attention not to change the polarity (+/–) of the
RS-485 device when connecting it.
Depending on camera's type, connection polarity can be
different.
For further information, refer to the respective PTZ
Camera's documentation.
Ex : DVR(TX+/–)
DVR(TX+/–)
22_
connecting with other device
ALARM IN
 SCC-C6433,35(RX+/–)
 SCC-C6403,07(TX+/–)
ALARM IN
PTZ device
Half Duplex Type
Data (–)
Data (+)
Full Duplex Type
 
Rx(+)
 
Rx(–)
 
Tx(–)
 
Tx(+)
Rear
Tx(–)
Tx(+)
Rx(–)
Rx(+)