Follow Mode - JRC Alphatron Marine AlphaDynaPos Operation Manual

Ship automation and navigation system
Table of Contents

Advertisement

2.4.12 Follow Mode

Follow Mode must be engaged for the DP system to follow one particular sensor. Set system into Auto-Position Mode to
make this possible (Figure 62: Position Screen on page 68) and perform the following actions:
Figure 62: Position Screen
1. In Position Screen select sensor as F.U. (Follow Up) in POSITION REFERENCE LIST, lower left on the screen.
Note Follow Up can only be selected if the sensor is not selected as position sensor. First deselect the
sensor to use for Follow up.
2. In the FOLLOW screen check the PRS INPUT check box (Figure 40: Follow Up (F.U.) on page 51).
3. Click the FOLLOW button, bottom right, to confirm Follow mode.
4. Enter target offset X and Y distance for fixed offset from reflector by clicking on the (yellow) OFFSET X and/or
OFFSET Y numbers. In the dialog that opens a new number can be entered.
68 | Operation