Siemens SIMATIC Panel PC 870 Equipment Manual page 112

Computing unit
Hide thumbs Also See for SIMATIC Panel PC 870:
Table of Contents

Advertisement

Hardware Information
Assignment of the IDE ports (X7, X10)
The primary IDE port is designed for alternatively installing a 3.5" hard disk
(connection via a 40-pin 2.54 mm pitch connector). The secondary IDE port is
provided for the optional connection of a CD-ROM (connection via 44–pin 2 mm
pitch connector. Maximum connection length of the data cables: 40 cm.
Pin No.
Short Name X7
1
RESET
2
GND
3
D7
4
D8
5
D6
6
D9
7
D5
8
D10
9
D4
10
D11
11
D3
12
D12
13
D2
14
D13
15
D1
16
D14
17
D0
18
D15
19
GND
20
NC
21
DREQ
22
GND
23
IOW_N
24
GND
25
IOR_N
26
GND
27
IORDY
28
Reserved
29
DACK_N
30
GND
31
IRQ
32
NC
33
AD_1
34
Reserved
35
AD_0
36
AD_2
37
CS1_N
38
CS3_N
39
HDACT_N
40
GND
7-22
Meaning
Reset signal
Ground
Data signal D7
Data signal D8
Data signal D6
Data signal D9
Data signal D5
Data signal D10
Data signal D4
Data signal D11
Data signal D3
Data signal D12
Data signal D2
Data signal D13
Data signal D1
Data signal D14
Data signal D0
Data signal D15
Ground
Not connected
DMA request
Ground
Write signal
Ground
Read signal
Ground
Ready signal
Reserved
DMA confirmation
Ground
Interrupt signal
Not connected
Address line 1
Reserved
Address line 0
Address line 2
Selection signal 1
Selection signal 3
Hard disk activity
Ground
Panel PC 870 Computing Unit Equipment Manual
Input/Output
Output
-
Input / output
-
Eingang
-
Ausgang
-
Ausgang
-
Eingang
Ausgang
-
Eingang
Ausgang
Ausgang
Input
-
Edition 12/01

Advertisement

Table of Contents
loading

Table of Contents