Siemens SIMATIC Panel PC 870 Equipment Manual page 105

Computing unit
Hide thumbs Also See for SIMATIC Panel PC 870:
Table of Contents

Advertisement

Assignment of a display to Display Select pins
Automatic configuration of one of 15 possible displays is performed by means of
the Display Select inputs. The Display Select inputs have pull-up resistors – in
other words, if these inputs are not connected, they go to High. The input has to be
connected to GND for them to go Low.
Pin-
LCD_SEL3
LCD_SEL2
Nr.
0
1
low
2
3
low
4
5
high
high
6
7
8
9
low
10
11
high
12
13
high
14
15
Panel PC 870 Computing Unit Equipment Manual
Edition 12/01
LCD_SEL1
LCD_SEL0
low
low
high
low
high
high
low
low
low
high
low
high
high
low
low
high
low
high
high
low
low
high
low
high
high
Hardware Information
Display-Typ
reserved
640 x 480 (VGA), TFT,
18 Bit
reserved
1024 x 768 (XGA), TFT, 18–bit
800 x 600 (SVGA), TFT, 18–bit
reserved
reserved
No display / DDC selected display