Removal Of Panel Board - Epson Perfection 4870 Photo Service Manual

Color image scanner
Hide thumbs Also See for Perfection 4870 Photo:
Table of Contents

Advertisement

Perfection 4870 Photo

4.2.3 Removal of Panel Board

1.
Remove of Upper Housing.
(Refer to 4.2.2 Removal of Upper Housing )
2.
Remove the two screws (C.B.P M3x8) which secure the Panel Board and then remove
it.
SW Connector Cable
Notches
Figure 4-10. Removal of Panel Board
Route the SW Connector Cable by passing it through the
notches of the Upper Housing as shown in
After installing the Function Button on the Panel Board in the
orientation shown in
Upper Housing.
Function Button
Figure 4-11. Installation of Function Button
DISASSEMBLY/ASSEMBLY
C.B.P M3x8
Panel Board
(7±1 kgfcm)
Figure
4-10.
Figure
4-11, install the Panel Board on the
Disassembly Procedure
Revision A
43