Troubleshooting - U-Line Refrigerator/Ice-Maker Combos User Manual

Echelon wine captain
Table of Contents

Advertisement

BEFORE CALLING FOR SERVICE
If the unit appears to be malfunctioning, read through NORMAL OPER-
ATION first. If the problem persists, check the TROUBLESHOOTING
GUIDE. Locate the problem in the guide and refer to the cause and its
remedy before calling for service. The problem could be something very
simple which can be solved without a service call.
TROUBLESHOOTING GUIDE
Troubleshooting — What to check when problems occur
Problem
No interior light
The unit is not
cold enough
The unit is not cold The door was left open
enough (Frost free
units only)

TROUBLESHOOTING

!
DANGER
ELECTROCUTION HAZARD
NEVER attempt to repair or perform mainte-
nance on the unit until the main electrical
power has been disconnected.
Possible Cause
Loose or burned out
bulb
Light staying on
Door gasket not
sealing properly
Dirty condenser coils
Airflow to front grille
blocked
Temperature not set
cold enough
causing the evaporator
behind the back wall to
fill with frost preventing
proper air flow and cooling.
!
Tighten or replace bulb.
See LIGHT BULB
REPLACEMENT
Adjust door so light switch
bracket contacts switch
plunger. See ALIGNING
THE DOOR
Adjust door. See
ALIGNING THE DOOR
Clean condenser. See
CARE AND CLEANING
Airflow must not be
obstructed to front grille.
See INSTALLATION
Turn control knob
CLOCKWISE to set
temperature colder.
Allow 24 hours for
temperature to stabilize
Turn off the unit to manually
defrost the evaporator.
See DEFROSTING.
31
Remedy

Advertisement

Table of Contents
loading

This manual is also suitable for:

15r75rBi-95Bi-9829rSp18 ... Show all